Search results

  1. T

    Anyone used a kit like this to screw/bolt a toilet down

    They were excellent. Thank you
  2. T

    Anyone used a kit like this to screw/bolt a toilet down

    Ah I get you put the bolt and nut in, in one go after the pan is in place. These fixings are usually ok then? I did think of throwing and using screws
  3. T

    Anyone used a kit like this to screw/bolt a toilet down

    Is like a bolt not much thread above so would have to get the height close to band on for the bolt to tighten
  4. T

    Pipe centre to centre measurements 2 x 110mm 45s.

    https://www.bes.co.uk/single-socket-bend-soil-vent-elbow-110mm-x-135-16120/ Like two of those put together. Does anyone no what size offset it makes
  5. T

    Pipe centre to centre measurements 2 x 110mm 45s.

    Think there official called single ended 45 socket bends
  6. T

    Pipe centre to centre measurements 2 x 110mm 45s.

    110 mm. Just 2 polypipe push fit single ended 45s
  7. T

    550mm basin wall hung

    Thanks for all the advice. This is the basin
  8. T

    Pipe centre to centre measurements 2 x 110mm 45s.

    Thanks I don't have two fittings to push together sadly
  9. T

    Pipe centre to centre measurements 2 x 110mm 45s.

    Does anyone know roughly the pipe centre to centre measurement if you push 2 single ended 110mm 45s together. What size offset does it create.
  10. T

    Cable for 2kw supply

    .
  11. T

    550mm basin wall hung

    Thanks I think there solid 6 inch breeze blocks
  12. T

    550mm basin wall hung

    Thanks for finding that
  13. T

    550mm basin wall hung

    Thanks just never fit one that heavy without a pedestal. It would be on a breeze block wall
  14. T

    Solvent weld and rubber boss/branch eye adapters

    I have some wastes.to run. I am doing 110mm in pushfit. And the 32mm and 40mm in solvent. What is best to connect to a boss/ the boss eye of a 110mm branch. Are the rubber ada
  15. T

    40mm boss adapters

    Thanks. I am wanting to go in to the eye of that in a horizontal water pipe run. With the 32mm pipe going in to it from above. Have always used the rubber connectors before but and thinking of going solvent
  16. T

    40mm boss adapters

    I want to boss into to the eye of a 110mm branch. If I use solvent am I best of with a solvent boss adapter to 40mm or can you still use the rubber ones? Thanks
  17. T

    Water hammer on shared main

    I know have just swapped stuff before when trying to diagnose water hammer and then the noise has carried on
  18. T

    Water hammer on shared main

    When they mentioned it before they did say it stopped when they opened a tap
  19. T

    Water hammer on shared main

    Is it something a pressure reducing valve could cause. Like the diaphragm is bouncing up and down in it
  20. T

    Water hammer on shared main

    Thanks. If stopped could be that
Back
Top