  1. G

    Extension of existing ring main

    May I ask 2 polite and simple questions? 1 What did you think you would gain or achieve from posting this as an opening link? 2 What kind of response did you think you would/should receive?
  2. G

    width of gas intake pipes

    Assumption is the mother of all f ups.... It sounds like you need an upgrade on the pipework. Also the next engineer who comes could find a 1.1mb or higher drop on pipework and shut it off. That could be middle of next winter. Couple of days without boiler..... Brrrrrrrr.
  3. G

    Pathetic water pressure

    Well that's the easy 1 done. Probably best to get engineer in now.
  4. G

    Pathetic water pressure

    Ok sorry the cold one will be the 2nd black handle from the right side. Is it straight or diagonal?
  5. G

    Pathetic water pressure

    Look under the boiler, toward the right hand side there should be a blue handle. Is it in line with the pipe or diagonally?
  6. G

    Mains 30he no heating or hot water

    It sounds like the temp knob is set wrong but it could be a faulty board from supplier. It can happen.
  7. G

    Pathetic water pressure

    Blockage in boiler or probably the cold iso valve is closed too much. It is usuall closed slightly to regulate the flow through the boiler.
  8. G

    Mains 30he no heating or hot water

    Joe just bog of will u or this will be another post u have ruined! For clarity, if you were to turn temp knob to max it runs to 50? Have you tried turning it down slightly (10%) to see if it then goes to 40?
  9. G

    Potterton Promax HE 15-Lights then ignition lockout-see pic

    No1 you have already done more than you should. No2 playing with the condense trap can lead to flue gasses coming into your home. Have you watched corrie recently? No3 get an rgi in who is experienced on this boiler No4 do you think that rgi's would spend thousands getting qualified if it...
  10. G

    will this work ok?

    Firstly I would imagine the blowers would have a connection for the room stat. So the 2 ports probably not required? Next I would put 2 smaller boilers in cascade with low loss header etc. and your pipe sizing is way off. Min 35mm up to 2nd heater.... It's a little far for me but if price was...
  11. G

    Gas supply to new hob

    Oh my god bl00dy aliens now??? Don't worry, Daniel craig will sort um ha ha :lol:
  12. G

    Gas supply to new hob

    Wow :shock: Are you really arguing with people who won't assist in someone breaking the law? Your medal is well deserved. The op has asked for advise and got the safest and best he could LEGALLY get. You seem to be 1 of those people who love to "stand up and stick it to the man". Grow up and...
  13. G

    Why is gas boiler installation so costly?

    Re chem flush. If existing system is running then I just put it in a couple of days before, if not I would either set up a pump to run round permenantly or if I had to I would put it in as I filled up and drain it out and put inhib next day or 2.
  14. G

    Why is gas boiler installation so costly?

    This is getting silly now..... Ffs it's possible to do a combi swap in a day legal and safe. It may not look the prettiest but safe n correct it is. It may even look ok ? It is also possible to make it last a few days if you are going to town on it powerflushing it, making the pipework look like...
  15. G

    Why is gas boiler installation so costly?

    I do however prefer my commercial installs. All the time you need with all the kit you like. With a bit of time you can make a plant room look really pretty :D
  16. G

    Why is gas boiler installation so costly?

    I did a swap last week same boiler. Reused existing per plumbing jig, meter below boiler 2 mtr 22mm gas changed flue (just to be safe) trvs on rads already and fitted rf prog room stat. Quick flush :wink: And chems in all good. Every so often you get a break.
  17. G

    Why is gas boiler installation so costly?

    For a cheap skate landlord I can do a combi swap in a day for£1000. However there will be little guarantee apart from they will need to throw money at it later... But I tell them this and they are ok about it. As for doing a proper job, set up correctly, flushed clean properly, with a decent...