Search results

  1. S

    Intergas WeatherComp sensor

    whats the other story?
  2. S

    Wiring Hive to oil powered central heating boiler

    You have compensated controls already...why downgrade with hive?
  3. S

    35mm 3 port zone valve with spring return?

    Not a recommended setup but,: https://www.jtmplumbing.co.uk/central-heating-controls-valves-c436/belimo-2-3-port-valves-1-2-to-2-c408/belimo-3-port-zone-valve-with-240v-actuator-powered-open-spring-close-p21843
  4. S

    WB Oil Boiler Lockout but not with covers off??

    there is a autore-set high limit thermostat. its in the manual. check circulation? covers off may be helping as there's little insulation on these buckets. to big for load?whats it heating
  5. S

    british gas

    contact b.g perhaps...??
  6. S

    Need help Identify expansion tank

    Okay then, goodluck
  7. S

    Need help Identify expansion tank

    Square ones replaced those round ones. Just buy a square one, with hose and it hangs on the hooks, once the round ones brackets are removed..
  8. S

    Need help Identify expansion tank

    Square ones replaced those round ones. Just buy a square one, with hose and it hangs on the hooks, once the round ones brackets are removed..
  9. S

    DIY heat bank - cylinder source?

    http://www.ebay.co.uk/itm/Thermal-Store-Hygienic-Buffer-Accumulator-Tank-for-biomass-boilers-wood-heating-/151748302522?pt=LH_DefaultDomain_3&var=&hash=item2354e756ba i ordered a custom steel one. good quality and insulation is very well made. Arthur is the person i spoke to.
  10. S

    combi fires up on its own

    answers to what
  11. S

    Oops oil boiler

    looks like a boulter camray wall hung outdoor. you may find the 'target brick' is obsolete
  12. S

    HRM Wallstar won't ignite

    am i invisible here? as also said by oilhead, close the air damper somewhat...
  13. S

    Baxi Bermuda 401 Back Boiler Problem

    who changed the thermocouple?
  14. S

    HRM Wallstar won't ignite

    what was the co2% in the flue gas? sounds as if its burning to lean. 300 is too hot. Take a note of the air damper setting, then close it slightly. a little bit at a time, to see if that improves ignition. or use your fga to check co2 is 12%...
  15. S

    Grant Combi 90/70 overheating

    Primary store stat changed? Hidden behind panel, try adjusting it down slightly with a small screw driver. It'll be painted in a fixed position. expansion vessel fexi hose blocked?
  16. S

    Boiler Replacement - The Big Guys vs The Little Guys?

    Not long completed a similar job although boiler was moved into loft, so more like 30odd meters of extra copper. Decent boiler fitted though and lpg. 2.5 days. Wireless programmer retained. Job done to current standards. little guy = 2400
  17. S

    Grant/Riello 530se Oil boiler wont fire, no lockout?

    You need a new burner motor, if you can use a multimeter safely, check for 50v from white wire on motor when its running..