  1. Exedon

    Whistling TRV

    Whilst current trv's are bi directional occasionally you get one that's noisy when closing. I'd be betting it's on return side of rad. Just change it and move on.
  2. Exedon

    newbie - 15mm plastick pipe Softener inlet (Mains) leak - Help!

    Not the best job on earth! Just get a couple of 15mm compression cones short end of 15mm copper and replace damaged section. Maybe a couple of wraps of ptfe on cones before assembly.
  3. Exedon

    WB heatlave not responding to stat requests - otherwise working

    That's the flow switch The 3 port diverter valve sits above the pump Grey plastic head . Which model heatslave? (Not the output) They have made quite a number! Has yours got green plastic on front panel?
  4. Exedon

    Weather compensation sensor with Hive on new combi boiler

    Agree with cp4i nice bit of kit with a 5 year warranty. We have a number fitted to ideal vogue's with weather compensation works really well.
  5. Exedon

    Not Getting Hot Enough!

    If you boiler is due for servicing crack on otherwise all the symptoms you are describing are almost certainly caused by restricted pipework. The picture i attached was from a 11 rad system that was somehow still sort of working ! Short Cycling very sluggish eventually boiler cut out on...
  6. Exedon

    Does this speed fit need any work?

    That's a rough mess IKEA unit with no service void? As above check for inserts id be putting the wm tap in the unit.
  7. Exedon

    Mains water shut - off valve handle question

    You have the valve that's fitted commonly in Anglian water area DO NOT overtightened they can lock down and not come undone! I've never done it but know others who have.
  8. Exedon

    Not Getting Hot Enough!

    I'll have a bet that the pipework is restricted with crap. Pic of one we sorted.
  9. Exedon

    Not Getting Hot Enough!

    Tank feed / open vent id be checking pipework with a magnet around open vent/ cold feed area.
  10. Exedon

    Soil manifold missing grommet

    That looks like a hepworth (wavin) soil manifold. They are still made so maybe spare grommets are available.
  11. Exedon

    Loctite 55 leaking radiator tail

    Well you have managed to do what ive never seen after many thousand of threaded joints and get a leak with loctite 55! We probably use more cord (don't bother counting) and tighten more . No you can't do any damage nipping it up more.
  12. Exedon

    Redfyre 100 oven thermostat

    Try speaking to Harworth Heating That looks to be a similar thermostat that's fitted to the thermorossi/bosky cooker.
  13. Exedon

    Can i sync the EPH CP4i using ember app to thermostat?

    If you got your ephcp4i as a set and you have linked the gateway to yor WiFi yes you can do all settings from your phone . It's a very quick easy set up.
  14. Exedon

    Old hep2o pipe

    Yes always insert same manufacturer as tube.
  15. Exedon

    Can someone tell me how to isolate my hot water please

    Lever valve on back wall with red handle If installed correctly should push down (fall to off)
  16. Exedon

    Why are there no old school heating engineers?

    I'd Certainly try a chemical flush you can probably do the drain down and refill yourself. If it works cost of power flush saved.
  17. Exedon

    Replace traditional with bar mixer shower

    As above ive managed to do it couple of time when pipework in stud wall using a fast fix kit. By the way matt black brasswear soon looks crap unless you have a obsessive cleaner.
  18. Exedon

    Why are there no old school heating engineers?

    For anyone with half a idea strait forward. Undoubtedly blocked near pump/open vent cold feed connection. Repipe add decent filter refill add X400 run for 4 weeks drain cold flush if needed . Refill adding inhibitor. Run of the mill stuff but not as well paid as throwing a combi on wall.
  19. Exedon

    Central heating layout. This should work, right?

    Take you spoke to Worcester? Doubt they know one end of a camray from another. Which mode of camray? 3 or classic? Perfectly simple to convert to sealed system done many some from new others retro fit.
  20. Exedon

    Why are there no old school heating engineers?

    But a young one ! First fitted a boiler (under supervision) in early 1969 vulcan autostat. Still working fitting a 70kw Grant next week. As above don't get a combi especially from s box slinging team.