  1. M

    Bypass valve

    I think you’re letting this get overly complicated. Don’t worry about the 20c drop across a radiator as no one gets that anymore. Are you using TRV’s on the radiators, if so that messes up the radiator temp drop as well so just ensure the radiators are balanced and let the TRV’s do their thing.
  2. M

    Is EPH CP4i Compatible with Worcester Greenstar 4000 Combi Boiler?

    There are ems to open therm converters available but their compatibility with your particular boiler would need checking.
  3. M

    Bypass valve

    Have you thought about temporarily replacing the ABV with a gate valve. You could then run all your tests with the gate valve closed but still be able to open it if the boiler complains.
  4. M

    Central heating layout. This should work, right?

    Any reason why you are repiping as an s-plan system rather than PDHW. With all the work you are doing now seems like a good time to replace the boiler with a pressurised system boiler that supports PDHW.
  5. M

    Radiator Sludge

    You are of course correct but if you look in the boiler manuals there is usually a section that states what the manufacturer expects a service to be but IME with my boiler this never happens therefore the boiler warranty is actually voided by the person doing the basic service. Luckily I doubt a...
  6. M

    Thermostat

    Get a Vaillant thermostat. None of the aftermarket ones will be as good.
  7. M

    Oil boiler, time between on/off/on and use of multi thermostats etc.

    A couple of observations for @ericmark ….. The Wiser system needs comfort mode turned on in order to work out when to turn heating on before the temperature setpoint change. This mode is off by default. The wiser graph is inaccurately plotting when the temperature rises, mine does the same. It...
  8. M

    Bypass valve

    Here is a thread with this same issue on another forum, looks like WB have an issue with these boilers…. https://forum.buildhub.org.uk/topic/46179-worcester-bosch-greenstar-8000-system-boiler-issues/
  9. M

    Wiring a relay to protect a programmer help.

    If the pump surges and fuses the switch in Tado then why doesn’t it fuse the switch in the motorised valve?
  10. M

    Wiring a relay to protect a programmer help.

    I thought the Tado sent a switched live to a motorised valve which then opens and sends a switched live to the boiler and pump. If so how will the relay help?
  11. M

    A spokesperson said: "Turning the thermostat up higher does not make your home warm up any quicker." Really?

    I have experienced with these types of smart thermostats that setting the setback temp no more than 2c below set temp is more comfortable and ensures a reasonable heat up time.
  12. M

    Optimum Boiler Temperature

    That’s not the only downside, it’s also emitting more CO2, costing more in gas, adding extra wear to components and shortening their life.
  13. M

    Vaillant eco tec 615 is it big enough

    what is the heat loss of the property?
  14. M

    Roomstat and TRV

    This only happens if "comfort mode" is turned on. IME it doesnt work very well if the room temperature drops more than a couple of degrees below the next set temperature.
  15. M

    Roomstat and TRV

    I would set both TRV's to max and if the "room" without the wall thermostat overheatst then turn the lockshield on its radiator down a touch.
  16. M

    Boiler has died

    Unless something is wrong with the wireless receiver and it blew the PCB in the boiler
  17. M

    Can I link a Wiser TRV head to a Wiser wall thermostat?

    Yes, just allocate the room thermostat to the same room as the TRV and the room thermostat takes over.
  18. M

    Drayton Wiser two channel replace of RWB9 Siemans Controller

    The gen1 and gen2 Wiser hubs use different backplates, I upgraded to the gen2 a few months ago hence how I know.
  19. M

    Fan In Flat Warm Roof

    It does make a difference. For a 150mm (6”) fan the gap needs to be 177cm2 minimum.