Search results

  1. B

    Worcester Heatslave won't relight

    Thanks again everyone. Turned out that the inlet pipe from the tank needed purging of air. I opened the inlet test point screw until gas could be smelt, then closed it up and the boiler fired up nicely :) "Thats not much use unless you have TWO pairs of wellies to fit both front and hind...
  2. B

    Worcester Heatslave won't relight

    Hello, thanks for your replies. Yes there is a good spark at the igniter. I have also tried opening the spy glass and using a spill, but still nothing. There is no smell of gas at all, just soot, so it looks like the 'muck in the pilot' is the problem
  3. B

    Worcester Heatslave won't relight

    Hello I've searched the FAQs etc, and haven't found an answer to this anywhere, so here goes: Worcester Heatslave 9-24 combi (old!) running on LPG. I stupidly ran out of gas and the tank was empty for 10 days till the Calor tanker came and refilled. The cooker is working, so I know I have a...