Search results

  1. D

    Texecom Sensor and Cable near Electrics

    Hi 9 months ago renewed alarm with wiired Texecom Premier Elite and Texecom dual sensor in kitchen. All working great. Building inspector wants an extractor fan in the kitchen and wiring for the isolator switch will be close to the sensor and cable of the dualtec sensor. Is that a problem or...
  2. D

    Kitchen Extractor Fan

    Final inspection by B Control and the inspector told us that we have to have a mechanical extractor in addition to the downward sucking recirculating AEG Hob extractor. All wiring done and signed off by our builders regular Spark. I can take power supply for one off the lighting circuit and...
  3. D

    Texecom Premier Elite Part Set

    So with good advice thanks SecureIAm and SparkyMarka the system is installed and have tested at the weekend with the Wife in the Garden. Works ok. But, struggling with night time part set. Night time I want to have the Garage (Texecom DT) and patio doors - (normally closed CQR sensors)set . So...
  4. D

    Connecting Odyssey Bell to Premier Elite Panel

    So all PIR's etc fitted and last lap is bell to panel .Bell was previously connected to Gardiner Panel and dont want to blow it at the last lap so before I power up can I ask the experts. Looks like the same 5 terminal on both the panel and bell..... See pic of panel and bell box...
  5. D

    Texecom Premier Elite 24

    The day has come to get the rest of the kit to fit my Texecom alarm. Premier elite 24 Wired system -thanks Sparkymark for recommendation- with 7 PIRs( CAPTURE-) and a door contacts. Oddysey Bell fitted on old Gardiner system, so all Texecom. Re-using original 6 core wiring. Could I have a...
  6. D

    Odyssey 3 Bell added to Gardiner 580 Panel

    So did my research on here and thought I did it right. Made the rookie mistake of not putting the panel into Engineer Code beacause I dont know it. No light on bell or strobe and now panel seems to be dead. The keypad has no light on it. I have checked fuse and that is ok. Current on all Zones...
  7. D

    New Odyssey 3 Bell on old Gardtec Panel

    Hi Guys Finally got around to changing system over to Texecom Panel as recommended by Sparkymarka and first step is new bell as weather dry - so going from old bell to Odyssey 3 Wiring in existing Gardtec panel shown along side terminals on new Texecom Bell - At this point if all I have is...
  8. D

    Texecom System

    Morning All So, in the process of replacing old Gardiner 580 due to a new extension and took Sparkymarka’s advice and bought a Premier Elite 24 control panel. Existing system all wired with cables marked as to which zones they serve so should be easy to connect. Need some guidance on additional...
  9. D

    Replacing Gardtec 580

    Moved into a house with a Gardiner alarm (580) and it is wired. I want to renew all PIR's and add one to the garage and replace the keypad , bell and control box . The wires (6 core) are marked so should be easy and I will run new cable to the garage and door sensors on the patio door. I like...
  10. D

    Insulated Plasterboard

    Hi Am building a single storey extension and the builder has left the plastering to me as at one point we knew a good plasterer.... His wife has produced twins so out of action for a bit. However, the Architect has specified insulated plasterboard for the ceiling (warm roof construction). The...
  11. D

    1996 Resin Kitchen Sink Waste

    Can anyone help I have a leaking sink from the 90's because the plastic fitting that goes in from the top is broken- the dia is approx 47mm and the part underneath is approx 70mm taking standard 1.5 inch waste Anyone know what I should be asking for -is it like a bath waste ? Thanks Derek
  12. D

    Replacement for Pyronix Paragon

    I have a 22 year old system with a Pyronix Paragon control panel 6 PIR's and bell. Original installer (RAINBOW) no longer in business near Northampton. Control panel has a fault and we have not used it for a while. I called Pyronix and they said better to chuck away the old system-and start...
Back