  1. J

    Mains powered smoke detector fault

    Replace smoke detector its knackerd.
  2. J

    Bathroom extractor fan

    Ive been asked to replace an inline extractor fan located in the roof space and am not to sure wether this work is notifiable as works are in the loft. Bathroom has all supplementary bonding ect, and i will issue a small works cert but do i have to involve local authoritys. Thanks
  3. J

    veritas r8 plus alarm ?

    Without engineers code there isnt a great deal you can do, not to sure if you can reset nvm on r8. alarm company shouldnt charge more than 60-80 pounds
  4. J

    Menvier TS690 Part Set Problem

    Sounds like the lec is faulty but before you change it make sure it is wired correctly disconnect power A or B leave off for a few seconds then put back in terminals (be careful not to short) and do a relearn check that pirs are wired correctly as there are many things this fault could be. If...
  5. J

    Menvier TS690 Part Set Problem

    Go to engineers menu 1 and press c to relearn hardware hopefully an exceptance tone will be heard and it should see them zones if not maybe a wiring fault, hard to diagnose fault without going through all the programing or being there.
  6. J

    Menvier TS690 Part Set Problem

    How many zones are there in the (zone expansion box) and is that called a lec or a node? and breezer is right nothing to do with outputs
  7. J

    Menvier TS690 Part Set Problem

    A Ts 690 is a 6 zone panel, zones 7-8 and 9-10 are either took from a lec or rkp (remote key pad) my guess is it is not seeing them zones as the lec and keypad have not been addressed properly or maybe a relearn is needed check behind rkp and lec and make sure they have different addresses.
  8. J

    External influence tripping RCD on TN-S system?

    Ive had similar problems in the past and rcd hasn't tripped on half test change rcd could be mechanical fault with it.
  9. J

    Pir what a pain

    Thanks gary i could have done it a differant way but what was important was id done it correctly.
  10. J

    Unswitched Fuse

    Is there supplementary bonding to light or shower /shaver in bathroom from heater, its not just metal pipes that need bonding its also any thing that is electric in any zones, your ok in zone 3 as long as supplementary bonding is in place.
  11. J

    Pir what a pain

    certainly was on trip lock saves a lot of time. take your advice on shorting out at mains should have thought of that but that socket had highest zs so tested from there funny thing was ring from end to end was L to L 0.08 N to N 0.08 E to E 0.16 ohms only had 3 doubles and 2 spured singles on...
  12. J

    Pir what a pain

    Its a tncs and measured ze was 0.20.
  13. J

    Unswitched Fuse

    Is ring rcd protected? is supplementary bonding in place? what zone is the heater in?
  14. J

    Pir what a pain

    Today i was doing a pir for a client after visually inspecting parts of the house it became apparent that a 6mm old cooker cable had been used to supply a ring main wired in 2.5 to the kitchen. Obviously it had been terminated in a jb some where as there was no evidence of a 6mm cable to any of...
  15. J

    Alarm keypad identification

    to change code = 6 enter, original code **** original code again**** then new code ****
  16. J

    kitchen make over and the new regs

    Reason is what about boiling an egg and it boils over onto a switch protected at 30-32 amps non rcd protected? steam from the sauce pan entering a switch day in day out not gonna do the contacts much cop, just not good practice in my opinion.
  17. J

    kitchen make over and the new regs

    I certainly would not sign off the work if ccu was above the hob would you?
  18. J

    Wireless or Wired Burgular / Fire Alarm System

    Same here, but if it must be wireless ive found the powermax to be good and reliable. Fairly expensive but worth the money in my opinion.
  19. J

    scantronic 9930 k01 tamper

    Take off keypad and reposition tamper spring it should click when fitted back.