Search results

  1. S

    Vaillant 937 plus Hot water flow

    Hello All, i need some advice. I have just installed a vaillant 937 plus boiler in the loft and just had it commissioned. I am concerned as to the amount of hot water i am getting out of it, because it seems to be poor. When i turn the tap on for the sink in the bathroom the pressure appears...
  2. S

    Fixing ridge tiles ?

    Hi, My Ridge tiles on the roof are starting to come away so i was going to fix them properly over the next couple of weeks ( weather permitting ). Do you just use a mix of sand and cement to fix them or is it something else. Thanks
  3. S

    Pressure relief pipe

    Hi, I have a vaillant 937 plus boiler that i am piping up myself before getting it commissoned, But want to make sure of one thing. Does the pressure relief pipe need to be connected to drain off or are these normally open ended ?
  4. S

    Vermin Guard

    Hi, I have just had a quote for new fascias and sofits and when i asked about vermin guard i was told that they cant fit it because of the tiles on my roof sit hard against the fasia board. They say that they fit the guard but because of the type of tiles, they cant. Is this true ? The tiles on...
  5. S

    Gas supply for Vaillant 937 / Copper or Plastic

    I wonder if anyone can help me??? I have chosen a new Vaillant 937 boiler to go up into my loft and was told to run 2 X 28mm pipes to the boiler for the gas supply. I cant understand why i would have to do this as the gas meter has a 22mm connection and so does the boiler. I did read somewhere...