  1. bevelsingle

    I have attended an ACE HIGH combi and the fault I have is that it will go through the start-up...

    I have attended an ACE HIGH combi and the fault I have is that it will go through the start-up sequence, the burner strikes up then after about 2 secs it drops out and the 'Power' LED (green) flashes and needs to be manually reset. I have gone to the manual and can find no reference to flashing...
  2. bevelsingle

    Miele W842 Washing Machine Rinses Light Flashing

    Hi I have the same on my Novatronic 520 Can someone tell me where to find the pcb in question please. I have the lid off and the front panel off and the main control board out (that was a game!) but am beginning to think I am barking up the wrong tree. Please help!! :(
  3. bevelsingle

    Glowworm 30ci boiler dead

    Brilliant! forums do work :) Glad to be of some help.
  4. bevelsingle

    Isar30 L9 Fault

    Yep, pump is free. If I came to the job fresh I would suspect PCB (have replaced plenty as most of us have), but on re-filling, the boiler ran DHW first off but stopped when CH run. :?:
  5. bevelsingle

    Glowworm 30ci boiler dead

    With ollski, we have an estate with about 100, record so far, 4 in two weeks last year! have been caught out as above caution but no huge problem as board can stay in van. Funnily enough, ordered one today, just remembered!!
  6. bevelsingle

    Isar30 L9 Fault

    Right, I know these are probably the worst boilers many will come across.:mad: I have an L9 fault Pressure good. Vented of air Pump is only receiving 40ish volts! (loom checked with pump disconnected) So I know pump will not turn, and hence why L9 but why low voltage. Boiler had not been...
  7. bevelsingle

    Glowworm 30ci boiler dead

    Don't rush into a new pcb (though it could easily be). some times ancillary components will 'kill' the display and when disconnected it will re-appear. Try disconnecting thermistors and other ancills. Obviously kill power before fishing around. if not, probably the board. May not be able to...
  8. bevelsingle

    worcesster 40Cdi conv.. 2 pumps needed on system!!

    I think what i shall have to do is try the by-pass on the dhw and 3 zones after the pump with the boiler operated pump and have the other 3 zones operated by the zone valve switches (which are t/stat controlled). thanks for all the help, first time i've visited the forum and i can't believe the...
  9. bevelsingle

    worcesster 40Cdi conv.. 2 pumps needed on system!!

    Paul, all of what you have said has gone through my mind, my only concern is that if the 'bypassed' circuit is the one controlled by the boiler it will always be on even when the boilers zones are not calling; would this have the effect of the return temp getting hot too quickly and operating...
  10. bevelsingle

    worcesster 40Cdi conv.. 2 pumps needed on system!!

    i have a system which requires 2 pumps (trying to make good some poor diy work) :roll: the system has 7 zones (6 ch, 1 dhw) and i need to split 3/4 using 2 pumps to overcome excessive circuit resistance. there is a new 40CDi conv and as i'm sure you know these control the pump and this is...
  11. bevelsingle

    'racing is everything; all that comes before and afterwards is just waiting!

    'racing is everything; all that comes before and afterwards is just waiting!