Search results

  1. J

    Shower Help Please

    Hi Everyone. It's been a while since I've posted in here so be easy on me if this question may have already been posted. I have a problem with the on/off tap of my thermostatic control for my shower. I believe that the shower is made by Grohe, but I can't find the actual part I need...
  2. J

    Help Required - Vaillant Ecotec Pro 28

    Agreed - but where do i go from here! So, diverter valve or PCB or anything else? :?
  3. J

    Help Required - Vaillant Ecotec Pro 28

    Hi Mickyg So as requested I have checked the resistance using a Robin Digital Multimeter Model OM 840. Set the switch to the following setting on Ohms and here are the results: Switch on 200, result = 0 (zero) Switch on 2k, result = 0 (zero) Switch on 20k, result = 12.038 Switch on...
  4. J

    Help Required - Vaillant Ecotec Pro 28

    Hi Mickyg, Have done as requested and used the multi-meter. Touched the two pins and it made a circuit. Tried to switch on the boiler with the pins disconnected (should this be open circuit) and boiler still shows same fault, s10. Still looks as if it calling for the hot water? Help?
  5. J

    Help Required - Vaillant Ecotec Pro 28

    Yeah I have a multimeter, can you just explain your method, step by step on how to complete this test? Just so we are singing from the same hymm sheet. Thanks Mickyg.
  6. J

    Help Required - Vaillant Ecotec Pro 28

    Hi everyone, I have again this morning checked for leaking taps and pipe work and none found, to confirm the control operation within the boiler I isolated the incoming cold water supply on the boiler and boiler stayed at S10. To confirm the: D4 = 74 D8 = 1 D22 = 1 D23 = 1 D35 =...
  7. J

    Help Required - Vaillant Ecotec Pro 28

    Who's BigBullShit? No, I dindn't, "jump the gun again" not sure i ever did... Stop cock was off when I checked the d's.
  8. J

    Help Required - Vaillant Ecotec Pro 28

    Hi Bunny, No worries, can i turn the stop cock back on now and program heat only for the night or we will all be freezing! The codes are as follows: D4 = 74 D8 = 1 D22 = 1 D23 = 1 D35 = 100 Hope the above helps! Thanks Bunny!
  9. J

    Help Required - Vaillant Ecotec Pro 28

    OK Bunny, 1/4 turn, now off. :shock:
  10. J

    Help Required - Vaillant Ecotec Pro 28

    Take that back, boiler went through a cycle, S11, S13 then back to S10, tap now dripping.
  11. J

    Help Required - Vaillant Ecotec Pro 28

    Bunny sorry, what did i do wrong? Boiler is on. Have turned off the cold water at the stop cock. have opened the hot and cold tap. The boiler seems to be static on S10. Have checked d36 and the display shows 0 (zero). Have checked second pipe in from the left underneath and its very...
  12. J

    Help Required - Vaillant Ecotec Pro 28

    Right, turned off stop cock and opened cold tap till nothing, closed then opend hot tap. Boiler not gone to S4, still on S10 although it did seem to go through a scan of S numbers but then back to 10. Have checked the second pipe in from the left and hot, very hot! checked d36 and it shows...
  13. J

    Help Required - Vaillant Ecotec Pro 28

    Does the hot tap need to be open? And the boiler left on i guess.
  14. J

    Help Required - Vaillant Ecotec Pro 28

    Everyone, Have got the multi-meter out and tested terminal 4, there is definitely 240v there. Have pressed the "i" button and the fault is sticking with S10 which, according to the manual is "Hot Water Demand". The heating is now on constant, stat turned up full (its not wireless) and...
  15. J

    Help Required - Vaillant Ecotec Pro 28

    Interesting... I'll try it. Is there a particular way the I button should be pressed? Am I switching off then on with the finger held on it? The diverter valve does move, it will centralise and stuff so it might even not be that? So, if I put the CH on constant, that’s a demand for...
  16. J

    Help Required - Vaillant Ecotec Pro 28

    Hi, Have tried this but no error code comes up, just changes to the BAR pressure and the actual temp. Driving me crazy now. Again last night had to blag the boiler via the d70 setting but can’t keep doing this long term. Seems strange, green light on the boiler, could it be the diverter...
  17. J

    Help Required - Vaillant Ecotec Pro 28

    LOL, not like that at all, sometimes its just easier!
  18. J

    Help Required - Vaillant Ecotec Pro 28

    Yeah, have done the d96 but no good, still dont kick in. Constant green light as if all is OK but nothing but cold rads. Tell me again re the multimeter, whereabouts as i drop the panel. Have you got an instant msgr program? do you wanna pm me with your addy if you have and you fancy a chat?
  19. J

    Help Required - Vaillant Ecotec Pro 28

    Hi, I have a Vaillant Ecotec Pro 28 boiler, installed from new prior to me moving into my new home 12 months ago. Suddenly, over the last week the heating has suddenly stopped working. Hot water is fine, but no heating. This seems really strange. I have totally drained down the system...
  20. J

    How do I remove emulsion from Velux Timber Window frame?

    Hi Everyone, I'm new on here so please be gentle. When painting the walls in the loft conversion we have got paint on the timber Velux frame. We have tried to sand it off but are struggling, does anyone have some quick helpful hints to remove it? Also, the frame has gone a bit black from...
Back