  1. Q

    Clunking noise - Desperate - Please advise.

    Don't know. The system (pipes and boiler) si old. There is a rattle if the CH circulator is on the lowest speed. MickyG - If I could live with the noise I wouldn't be asking for advice.
  2. Q

    Clunking noise - Desperate - Please advise.

    Yes, I do, behind a wall. But no motorized valves.
  3. Q

    Clunking noise - Desperate - Please advise.

    I have no valves at all on my system. C plan is where the valve is on the gravity hw circuit, right? Then that would make no difference to my annoying clunking noise.
  4. Q

    Clunking noise - Desperate - Please advise.

    Ah, so I am assuming isolating the pump stops any movement of water up the flow pipe via gravity? Therefore, if I was to put in a 2 port motorised valve on the flow pipe, to open when the pump starts, that should cure it? I can't get to the check valve as it is behind a wall! Thanks for the...
  5. Q

    Clunking noise - Desperate - Please advise.

    Thanks for the reply. It's not kettling. It's not coming from the boiler. Had kettling before and treated the system with boiler silencer. It really sounds like a noise from a pipe. Besides why would kettling stop when the pump is isolated?
  6. Q

    Clunking noise - Desperate - Please advise.

    I have an old Potterton Kingfisher floor standing boiler. My hot water is gravity fed and my heating is pumped. The problem I have is there is a loud "clunk clunk" noise from somewhere (sounds like from a pipe). This noise occurs when the HW only is on, and when it gets to a certain...
  7. Q

    Cold rads

    Thermostatic valve pins may be stuck, and system may not be balanced correctly. All depends if the problem has just happened or got gradually worse.
  8. Q

    Megaflow and Central Heating

    Ended up re-packing the valves. Didn't need to drain down. Thanks anyway.
  9. Q

    Megaflow and Central Heating

    Thanks for your concern Tony. I am a capable guy, have done lots of plumbing on different systems, but have not worked on a megaflo system before. Have worked on combi systems and vented indirect systems plenty of times, so rest assured I will not be pumping the system up till it bursts! Just...
  10. Q

    Megaflow and Central Heating

    Just changing a couple of radiator valves for a friend. I am familiar with combis and unvented indirect systems, as I have installed lots of rad before. Never had to drain down a system with a megaflow. That's why I wondered if the rad system was pressurised, like a combi system. Thanks.
  11. Q

    Megaflow and Central Heating

    Thanks Mickyg. Just as I thought. I had also just seen a post on another thread sort of confirming this. Does this mean the CH system will be vented with header tank etc? Thanks again for your quick response.
  12. Q

    Megaflow and Central Heating

    Hi, Can somebody tell me whether the central heating radiators are under pressure when the system comprises of an unvented cylinder, like a megaflow, or is it separate? Many thanks in advance.