    Worcester Bosch Greenstar CD30I

    PS. what is open vent?
  2. P

    Worcester Bosch Greenstar CD30I

    Ben, Thanks for the time to reply. There was an imbalance, but i have now opened all the valves and stats and have red hot rads when the boiler starts. I can now get the heating on and controlling but when the HW is turned on the temp rises within 3 sec to 99 the U1 to U9 and purges...
  3. P

    Worcester Bosch Greenstar CD30I

    Morning All, I have a 2yr old Worcester Bosch Greenstar CD30I which has just started playing up and the Worcester engineers is strugling to explain it. I call it in after the unit purged on U9 code on teh display and then went cold. Its also showing the syphon fill code frequently. I had...
  4. P

    Friedland Gold - Reson8

    sorry that was 120mA not 12
  5. P

    Friedland Gold - Reson8

    i already tried that with the adition of the 12V switched o/p GND connected to RTN. Didnt work. Thinking i might have a dud bell box. The main bell box is wireless, and this second one takes 12mA flash current so Im hoping the panal wont blow.
  6. P

    Friedland Gold - Reson8

    SORRY FOR BEING THICK! DO YOU MEAN V+ TO TRIG GND TO RTN? LEAVE HOLD OFF's DISCONNECTED? MUCH APPRECIATED
  7. P

    Friedland Gold - Reson8

    Hey Guys, I have installed a new Fiedland Gold system which I would like to link to a second standard bell box (if poss) to have indication on the rear of the house. Problem is I cant make it worK. Control Unit ext -conn V+ [Permanent 12Vdc power supply output (100mA max.)] GND OUT...
  8. P

    bell box wiring

    no its pulled down to 11v. squarking stops when u lift the SRN wire. looks like compatability issue. Di Yale use 5V for SRN and 15V for STB? Either that or the control panel is FU!
  9. P

    bell box wiring

    near to 14v i just got through to yale and although he fobbed me off he said it may be incomatible with the reason8. which is maybe due to the voltage difference. im going to wait and call yale monday. it may be that i need to replace the bell box with another the same as the old one...
  10. P

    bell box wiring

    Thanks Breezer I have been trying something simular (but with the BELL left and right linked out to isolate it for now) I think the wet / previously damaged bell box has killed the control panel. There is 4.75V on the TRIG o/p (disconnected). Thus when this is connected to the 14V in...
  11. P

    bell box wiring

    Dear all, I have just had to repalce a faulty Yale (wireless) bell box and chose to buy one from a local screwfix outlet. Problem is I cant figure out the wiring between the two and could realy do with a little expert advice Control Panel BELL TRIG STB TRIG +12V -12V BELL TMP (LEFT)...