  1. R

    Baxi combi 105e dhw fault

    Thanks weargas, you were absolutely spot on. The pin behind the diaphragm had some limescale on it and a quick outing with the wire wool made it as good as new. It was also really easy, and I wonder if my model of boiler is slightly different from the one you were referring to. I simply had...
  2. R

    Baxi combi 105e dhw fault

    Many thanks for that weargas, I'll have a look and see how it goes. Regards RichM
  3. R

    Baxi combi 105e dhw fault

    Hi, Does anyone have any suggestions about this problem, please? RichM
  4. R

    Baxi combi 105e dhw fault

    Hi, I was wondering if anyone could help. My Baxi Combi Instant 105e has developed a fault over the past week or so. The domestic hot water works fine, but occasionally, the central heating won't switch in. When the fault occurs, all of the red temperature neons are lit (none flashing)...