  1. B

    Engineer leaving British Gas ?

    will do, thanks Tony.
  2. B

    Engineer leaving British Gas ?

    Hello everyone. Have been with british gas now for 2 years and really want to leave, for many reasons but not going into details right now. Thinking of a move to Heat team, or Vaillant ? not sure just yet. Would be great to get a little feedback from anyone that has made the move from BG, or...
  3. B

    Ariston Boiler - contiuously igniting

    Oh very sorry all. yes correction (take out) how would you know bg training is bad?
  4. B

    ARISTON MICRO COMBI - LUKEWARM WATER

    yes it could well be the pump. i would of said.
  5. B

    ARISTON MICRO COMBI - LUKEWARM WATER

    i take it by heat sensors, you have change the thermistors? when the boiler is on full tilt, that is with the hot tap open full, what its the burner pressure? does the gas valve modulate upto full gas rate and then back down when the tap is closed alittle? how about the pump? is it set on 3...
  6. B

    Ariston Boiler - contiuously igniting

    that out a british gas contract. we are better.
  7. B

    air getting into heating system?

    the sysyem is sealed and so is under positive pressure. this is not an open vented system and not subject to positive and negative pressure. As i have said air can not be pulled in via the pump or rad valve or anywhere else. in use the system pressure can be upto 2 bar, and thats the whole...
  8. B

    air getting into heating system?

    Air can not be pulled in on a sealed system. the air has been trapped. has the auto air vent been left open on the appliance? this would help free the air in the system. you could try dropping the all the water out through a drain point. then refilling, bleeding each rad till you work your way...
  9. B

    British Gas Boiler 532

    To convert Kilowatts (kW) into a British thermal unit (Btu) value simply multiply the Kilowatts value by 3414 kW x 3414 = Btu Your boiler is 32kw 32 x 3414 = 109248 btu fit the green filter.
  10. B

    Hot Water Cylinder Set-up

    fit an S plan but add an extra zone valve, with is own controls. that is time switch and cylinder stat. when you branch of from the pump, fit auto by-pass first then have the pipe work split into three with a 2 port valves on each branch, have this close to the 10 way J/B as you`ll use less...
  11. B

    Boiler Loosing Pressure

    Does the pressure ever rise high to 3 bar? and have you seen water dripping fron the PRV termination?