  1. dilalio

    Is my radiator leaking?

    Pin will be leaking. They always do. Remove head and make sure pin moves freely up and down. This may stop the weeping or may not!
  2. dilalio

    Is my radiator leaking?

    If you've cleaned it up and it's reappeared then it's leaking. Leaks can appear when hot or cold or when transitioning from one to the other as materials expand and contract at different rates.
  3. dilalio

    Radiator Sludge

  4. dilalio

    Radiator Sludge

    In layman's terms... Sludged up system are present in 1000s if not millions of properties. National gas usage would be reduced dramatically if all systems were clean and treated.
  5. dilalio

    If its yellow... Don't let it mellow!!

    Ain't that right @HERTS P&D... That stalag-shyte has now dropped 3 metres down the stack! This means opening up the wall and cutting a section out of the stack, so that it can be pulled out... It's about 500mm long and hard as concrete! My Saturday morning job :sick:
  6. dilalio

    Radiator Sludge

    Only if a hard water area. Can't be arsed to look up if it is... Scotland, no idea without looking.
  7. dilalio

    Radiator Sludge

    BS 7593:2019
  8. dilalio

    Radiator Sludge

    https://www.installeronline.co.uk/heating/top-bottom-opposite-ends-tboe-trv-installation-what-installers-need-to-know/
  9. dilalio

    Radiator Sludge

    Have a chat with him. We all get stuff wrong sometimes. Valves may be bi-directional but radiators that are piped up TBOE are not! To the remote eye, it's fairly obvious what the elephant in the room is. For the sake of a couple hrs work change the boiler F&R round and see what the...
  10. dilalio

    Recommendations on a Macerator?

    I'll fit one new but that's as far as I'll go!
  11. dilalio

    Radiator Sludge

    TBOE
  12. dilalio

    Radiator Sludge

    And yet sludge is the biggest cause of CH problems and boiler breakdowns. And is why the government have now introduced quality checks for system water as it also affects energy usage.
  13. dilalio

    Gravity based back boiler CH system - Advice needed.

    Ideally, but rarely done.
  14. dilalio

    Gravity based back boiler CH system - Advice needed.

    You don't need a product. You just connect the feed and vent to the pipe in an "H" configuration, the correct way around and the correct distance apart. 2 tees is all you really need... Use compression then you can always take it apart for future attention!
  15. dilalio

    Boiling water tap. Vent pipe

    Discharge from unvented should point down to ground not out at the open world. Does the kit in the photo have a NRV in the clamp-on fitting? Where's the NRV?
  16. dilalio

    Gravity based back boiler CH system - Advice needed.

    I wouldn't worry too much about the cylinder not getting to 60°c.
  17. dilalio

    Boiling water tap. Vent pipe

    I'd stick it through the wall and turned down to point at floor. Doesn't have to be trapped that way.
  18. dilalio

    Shower trap strange goings-on

    If it works as open vent, then add pipework with a fall on it... Enough to allow condensation (and rain ingress) to run back down to the stack. And yes, use the proper drainage flexi.
  19. dilalio

    Boiling water tap. Vent pipe

    Is there an external wall behind the unit? If so, discharge the tundish to outside.