Search results

  1. N

    Ideal ISAR Boiler - Pressure rising above 3 bar & leakin

    If it helps I had work done over the summer in plastering the walls and had all the radiators (except the bathrooms) removed off the wall. Boiler was drained. I was still experiencing the loss of pressure prior to that but only had to top every two weeks or so and never came across any error...
  2. N

    Ideal ISAR Boiler - Pressure rising above 3 bar & leakin

    Dan, the reason why I asked the OP is because the symptoms my boiler has are the same as the OPs and I wanted to know a ball park figure on how much it would cost to repair including how much effort it would require a competent gas safe engineer to do repair this. I am fed up with this boiler...
  3. N

    Ideal ISAR Boiler - Pressure rising above 3 bar & leakin

    Thanks Gav, But I have had a registered Gas plumber in and his response is the pump and my problems are similar to gardernersweekly. I wanted to know how much he paid for the blockage in the boiler to gauge whether it is feasible to repair. If the cost is high then I will look to replace the...
  4. N

    Ideal ISAR Boiler - Pressure rising above 3 bar & leakin

    Message to gardnersweekly. Please can you let me know what the cost of your repair was Thanks Naz
  5. N

    Ideal ISAR Boiler - Pressure rising above 3 bar & leakin

    Hi I am experiencing the same problems as yourself. I have the Ideal Isar HE24. When the CH is on pressure goes from 1 bar to 3 bar with 10-15 minutes. Also when the boiler cools after CH is turned off it appears to have lost pressure not immediately but it does and I have to top pressure up...
  6. N

    Drying plasterboard or plastered ceiling

    Thanks Richard, I will give this a go. Sounds like it may do the job.
  7. N

    Drying plasterboard or plastered ceiling

    Hi All, Firstly, thanks Richard for your Advice. In answer to some of your questions. The house is about over 100 years old (late 19th Century). In 2004 we had the walls and ceiling skimmed so the work is still relatively recent. It does looks as though the ceiling is platerboard which has...
  8. N

    Drying plasterboard or plastered ceiling

    Hi All, Last night I had to deal with an unfortunate accident. I had just come out of the shower and switched it off (at the shower and not the mains). I have a triton electric shower. I then turned the shower (at the shower) on to clean the bath but the high setting would not work so I used...
  9. N

    Honeywell wireless thermostat lost comms

    Thanks D_Halisham, Yes, I think you're right about the fact that the RF box is dead. Is it sonething that is easily installed or does an electrician or a gas fitter have to install it. Also, do you need to buy the pair (stat and rf box) as the boiler fitter who looked at ours suggested that...
  10. N

    Honeywell wireless thermostat lost comms

    Hi, Currently I have overridden the RF and stat by using a wire between L1 and L2 terminals. These terminals had no cables/wires in. As for the other 3 terminals these have cables in. I think you may be right in so much that the RF box has gone kapput. I've googled to find out how much...
  11. N

    Honeywell wireless thermostat lost comms

    Hi, I'm pretty sure that the STAT and RF box are communicating to each other so I feel there's no fault there. However, the fault is between the RF Reciever box and the boiler (this is the bit which is hard wired) It will not switch the heating off or on as is the case at the moment, the hot...
  12. N

    Honeywell wireless thermostat lost comms

    Hi guys, I have the same honeywell Programmer Stat and RF box and I have a fault with the RF transmitter where it does not send the signal to the bolier to switch off. We have put up with this for 8 weeks. Today the opposite has happened the boiler switched off but the RF box will not send...