    Boiler cuts out

    Hi All, Thanks for all the input, Hmm anything else I can say? It a Worcester Bosch Highflow 400 RSF gas boiler. Pressure drops over a day or so to about 1.2bar from 1.5bar and it cuts out but will restart easily on pressing the refire button under the control box. Then keeps cutting out at...
  2. T

    Boiler cuts out

    I have replaced the badly kinked flexible hose and re-set system but boiler still cuts out after a couple of days. Anyone know of a valve or switch that might be faulty? e.g. air flow pressure switch? water diverter valve? Pressure relief valve? :cry:
  3. T

    Boiler cuts out

    I have now just replaced the flexible hose to the expansion vessel. No kinks! When letting air out to reduce pressure in the expansion vessel there was indeed some water coming out. Also a lot of water came out of the expansion vessel when I removed the flexible hose from it. I remember someone...
  4. T

    Boiler cuts out

    Cut out again last night. I have noticed that the expansion vessel flexible hose is badly kinked top and bottom - anyone think this is problem? When expansion vessel is raised back to it position is when it kinks. I have tried to realign it but it memorises its old kink position! I might...
  5. T

    Boiler cuts out

    No dripping from the outside pressure relief pipe (small copper pipe near ground level). I don't know how to 'click' it but I know its the red knob on the left with '3 bar' written on it is the pressure relief valve. The 3 litres that came out I assumed was replaced when I added more mains...
  6. T

    Boiler cuts out

    Hi All, The boiler ran successfully for 3 days before cutting out this morning(longer than usual). The system water pressure had dropped by 0.3bar to about 1.2bar. I topped up with mains water to return to 1.5bar fired up and all ok for now. The pressure had been a constant 1.5 for 2.5 days...
  7. T

    Boiler cuts out

    Thanks Gigz and Tony! I'll see how it goes over the next few days. Nick
  8. T

    Boiler cuts out

    Tony, All done as suggested. I guess I run it and see what happens now? System pressure would not go to exactly zero even with bleed valve completely out but that might be the pressure gauge not accurate. About 3litres of water eventually came out after repressurising the expansion vessel to...
  9. T

    Boiler cuts out

    Tony /agile, thanks for your suggestions by the way! It all helps.
  10. T

    Boiler cuts out

    Hi Agile, How do I reduce the sytem water pressure to zero? Setting the expansion vessel to 0.9bar I can do and also I assume repressurising the system via the inlet cold water is easy too.
  11. T

    Boiler cuts out

    Thanks for suggestion! Pressure was at 1.3bar so have pumped to 1.5. I guess that the difference of 0.2 below correct level may not be of significance? But its worth a check and set at correct level.
  12. T

    Boiler cuts out

    Pressure drops about 0.2 bar when there is a demand for hot water (i.e. boiler comes on) and then when demand stops and boiler stops heating it goes back up the 2 bar it 'lost'. The pressure increase events are rare. Pressure not constantly rising.
  13. T

    Boiler cuts out

    We have a Worcester Bosch Highflow 400 about 9 years old. It cuts out every other day so needs pressing the restart button after I refill with water from the mains connection. This gets the pressure back up. I think it cuts out when pressure has dropped to about 15psi (1bar) so I refill till...