Search results

  1. B

    Noisey Boiler

    Changed the entire assembly and transfered the old uswitch and now all is working fine. Many thanks for everyones help. Regards Brum.
  2. B

    Noisey Boiler

    Hi, Can't tell yet weather or not its the microswitch or pin mechanism but will check this shortly. Suspect though that it would be easier to change the entire assembly. Regards Brummie.
  3. B

    Noisey Boiler

    Hi, I checked the hot water flow switch and found that when the hot water tap is switched on the microswitch operates straight away, however, when it is switched off again the microswitch can take up to 15 seconds click off. I am assuming that the microswitch should operate immediately in...
  4. B

    Noisey Boiler

    Thanks for the reply. Could you explain the function of the water flow switch and why it would cause the pilot light to go out? Brum.
  5. B

    Noisey Boiler

    Hi, I have a Potterton Puma 80 boiler and just lately the pilot light has started to go out when the hot water is switched on. The hot water arrives at the taps but when the tap is switched off the boiler makes a sound as if it has boiled dry and then the pilot light usually goes out. The...
Back