  1. A

    Boiler pressure gauge- random drops

    I would be checking prv for any drips and checking condensate for same,with past experience has always comes down to the heat exchanger not to uncommon on these boilers.
  2. A

    Worcester highflow 400 poor circulation

    good morning I have the said boiler but with poor central heating only 1 radiator heats up and nothing coming back on the return,pump has been changed and diverter valve,new isolation valves and manifolds and plate as there were other problems,my question is what else can I be looking at?
  3. A

    Deleting lavasoft

    No nothing at all I've looked in the registry and lavasoft is there but I just looked
  4. A

    Deleting lavasoft

    Hello I'm in the process of installing talk talk security software its gets so far and then says that ad-aware is incompatible and that I need to delete it but I cannot find it anywhere not sure what to do where to find it,I've looked program files/uninstaller but it must be on there somewhere...
  5. A

    clunking sound off hot water mixer tap

    hello,slight problem with hot water tap in that it makes a clunk sound when turned off from a main condensing combi boiler,i`m thinking may be loose washers in tap am i on the right lines? does`nt seen to happen on any other tap thanks in advance
  6. A

    Britany 80 Combi - Clicking 60 light flashing

    i have found a main common problem with these is the primary flow thermistor situated on the left hand side i belive 2 purple wires coming off it.There are two thermistors which are identical the other just behind to the right that one relates to the hot water flow not usually the problen,I...
  7. A

    Promax 15 HE - explosive ignition

    jlm is right get him back,a comon problem with the promax is the burner failing and or the electrodes start up should be quite smooth
  8. A

    Potterton Performa boiler pressure at 3.00 bar when cold

    try turning off your mains and check if pressure rises
  9. A

    Potterton Performa boiler pressure at 3.00 bar when cold

    i would check your filling loop is not passing
  10. A

    Worcester 24i problem

    are there any flashing lights......can you hear the fan running
  11. A

    Dizzy girl needs advice on water hammer

    hi dizzy i would tighten the gland nut on the stop cock quite a common problem
  12. A

    Central Heating question

    i would guess there that your boiler is situated in a garage and the stat u refer to is a frost stat which will bring the boiler in if it gets to cold
  13. A

    main medway

    unfortunately you cant or i would`nt bother trying you will have to replace whole unit
  14. A

    Central heating help please.

    if header tanks is full of water and no air or water coming out of radiators when you try to bleed them it sounds more like you have a blocked cold feed,a negative point coming from the header tank and tee-ing off to radiators,with all the sludge you mentioned this sounds the most likely.You...