    No Hot water but central heating is fine.

    First thing to look at is the FEED and expansion tank in may be empty due to a stuck ball valve, if not then blocked feed pipe. If the coil is short of water (gravity feed system) the cylinder will not heat up at all due to no circulation. The heating can still work for a time but the gravity...
  2. P

    No Hot water but central heating is fine.

    As Dan say's draw it out or look in a basic plumbing book easy to work out.
  3. P

    No Hot water but central heating is fine.

    Because when the cold feed is blocked the system is short of water and the first thing to suffer is the coil on the cylinder hence no hot water.
  4. P

    Bath Trap McAlpine Bottle Trap Getting Clogged with Hair

    I generally find that the plastic pipe out of the trap has been cut with an hack saw and the rough cut has not been trimmed smooth, ideal for catching hair.
  5. P

    When is a 15mm thread not a 15mm thread

    Yes you will have to change the fittings for new ones. Around the time period you state some radiator valves did have a different thread on the nuts to the ones that we use now.
  6. P

    Vaillant VCW-sine 18 T3 W

    Having had 30years service from a Vaillant is all the answer you need, why not stick with Vaillant. "Ideal boilers" I would not go down that path for a number of reasons.
  7. P

    Hi Kirkgas the power point would be appreciated many thanks [email protected]

    Hi Kirkgas the power point would be appreciated many thanks [email protected]
  8. P

    F23 error Vaillant EcoTec Plus

    [/url] Not realy as this post is over a year old :roll:
  9. P

    honeywell will not pressurise?

    No it does not help What model boiler? What you are doing? What the boiler is doing? as requested more info needed. The three that have already replied to you are good lads and will help but you need to help them.
  10. P

    gas test ??

    So you are saying he has been working illegally for years
  11. P

    Vaillant EcoTech Plus boiler - Radiators not working

    Pressure needs to come down to about 1.3 and the boiler number is also a help.
  12. P

    Vallient ecomax pro 28e - frequent short bursts of running

    Sorry forget my advice thinking of different boiler :oops: I agree with Gas4you
  13. P

    Vallient ecomax pro 28e - frequent short bursts of running

    Is your boiler the Ecomax or the Ecotec pro 28 combination boiler
  14. P

    Vallient ecomax pro 28e - frequent short bursts of running

    It is probably the warm start for domestic hot water. To turn if off you need to turn the hot water control on the boiler to the off position then back to your setting. To turn it back on the control full on then back to your setting. Turn it off and see if that helps. :wink:
  15. P

    What the... ? Corroding copper pipes - pinholes.

    As Shambolic & Softus has said that the only way to solve your problem is to completely replace the affected copper. It was during the copper shortage that we were using imported copper that was a poor quality. I have had to replace lots with exactly your problem also tried lots of different...
  16. P

    Is the valve faulty?

    You can manually turn the valve about a quarter of a turn to close then back to open. If the valve is still passing hot water, then it needs replacing. Also when draining down see if the system is full of sludge if it is fill and flush out a few times as that may affect the valve operation.
  17. P

    Is the valve faulty?

    If you cannot manually turn the valve on and off then it is a drain down and replace
  18. P

    Noisy pipe since washer change

    Change the complete valve and that will sort it.
  19. P

    Neighbour requesting I move boiler vent installed pre 2002..

    It seems odd to me that your property extends over the next door boundary line. Maybe it is the boundary fence line that is in the wrong place because if it was between the two properties your flue would be on your side of the fence. Property deeds may hold the answer?