    biasi boiler problem

    Hi Tony, Well the pcb seems to have cured the problem, Although it is considerably different from the board that came out, looks totally different, components on the underside also unlike the old one it has 6 dip switches we were advised to set them all up apart from 4 seems ok anyway, Thanks...
  2. J

    biasi boiler problem

    Thank you for your help Tony, I can only go on what the engineer has discussed with Biasi and they seem certain it is the board and I hope so as at over £200 it is a costly error, If it gets changed I will of course send you the old board for your tests or whatever, apparently the...
  3. J

    biasi boiler problem

    Oh Sorry, that was with the fault present, it was displaying those lights! The engineer phoned Biasi and they reckon it is the pcb that needs changed,
  4. J

    biasi boiler problem

    When in diagnostics mode, and running the bath taps the two green lights indicate DHW operation, flashing alternately whilst the red ligh remains off!! any ideas please?
  5. J

    biasi boiler problem

    The chap is coming back on Monday so he will put it into diagnostics and see what happens from there, Thanks for your advice and help
  6. J

    biasi boiler problem

    Hi Tony, I assume the manual will tell the chap how to get the board into the diagnostics mode? Your help is appreciated
  7. J

    biasi boiler problem

    Thanks for that Tony, The serial number is N009660307 GB i think it has just one board, the three lights, only the left hand one which when it is assembled can be viewed was flashing green the other two remained unlit, this was when the problem was present. the unit was fitted in may 2007...
  8. J

    biasi boiler problem

    Thanks boilerman 2, I beleive he checked the air pressure switch yes!
  9. J

    biasi boiler problem

    Tony, The Model number of the boiler is M90E - 32S GC 47 - 970 - 21, It's all I can see on it, Thanks, John
  10. J

    biasi boiler problem

    Thanks for your replies chaps, Tony,I shall revert back with the model number asap, The biggest problem has been that the fault is not always there, ie when the chap serviced it it was fine, at that time but as I had described the fault the chap changed a wee sensor part that goes beside the...
  11. J

    biasi boiler problem

    Hi, I am having a problem with my Biasi 32s combi boiler, It fires up for about three seconds shuts down and the lock out light flashes four times but doesn't stay lit, then goes through the cycle again and again, it smetimes works ok but after about an hour it starts this again, Had a chap...