    Ferroli Optima Honeywell VMF7 PCB Relay Fault

    Hi, the guy who repaired mine in Sheffield is Pete Hartley http://www.hartleyelectricmusic.co.uk/repairs.html He's a real wizard with electronics, very helpful and won't 'lift your leg' with the cost. Cheers.
  2. H

    Ferroli Optima Honeywell VMF7 PCB Relay Fault

    John, sorry I can't trace the eBay seller as it was some time ago but item 130364321191 looks like the one from my memory. Obviously you'll need to check the spec against the one one the board, DPCO etc but I think that's the one. As I said before though, unless yours has been chattering away...
  3. H

    Ferroli Optima Honeywell VMF7 PCB Relay Fault

    Quite right last poster, the capacitor does have a + & - leg which I was just logging on to re-post this info. So just check which way round before you desolder the original. Alternatively, you could get a heating engineer out to put you a complete new PCB in. I just posted the info so people...
  4. H

    Ferroli Optima Honeywell VMF7 PCB Relay Fault

    Hi John, I'm no heating engineer but it's a pretty straight forward repair. Assuming you've got to the PCB by unscrewing the front, switch off the power and take some good photos of which wires go to which connections - label them if need be. Pull off all the wires, unscrew the PCB and take it...
  5. H

    Shower trips MCB 2 mins after shut-off

    I tried leaving the shower running last night for about 15 minutes (much longer than usual). Again, no tripping the MCB until about 2 minutes after shower and DP switch turned off. I'm going to fit a 45A MCB anyway but am still puzzled why the 40A one fitted doesn't trip whilst the shower is...
  6. H

    Shower trips MCB 2 mins after shut-off

    You're right, I think it is 10.5KW at 240V. As for when it trips, it's fine whilst the shower is running but a couple of minutes after it's shut down (and even if the DP switch is turned off) the Circuit Breaker trips. So it seems it's heating up after everythings turned off which I don't...
  7. H

    Shower trips MCB 2 mins after shut-off

    Thanks to all for your suggestions. The shower is rated about 10KW at 240v and the 10mm cable runs under floorboards so plenty of ventilation. I'll fit a new DP switch, 45A MCB and check connections. Thanks again!
  8. H

    Shower trips MCB 2 mins after shut-off

    I have an 10kw electric shower which is run through a double pole pull switch which is connected to an individual 40A MCB + RCD box connected direct to the meter. All cables are 10mm. About 2 minutes after the shower is switched off the MCB trips. A new shower has been fitted and still the...
  9. H

    ferroli optima 701 no ignition for pilot light, buzzing ry 4

    The chattering Relay is the one to the far right of the PCB and often looks burnt due to the sparks caused as it chatters. After much searching and testing I've managed to cure this fault for about £6. The chattering relay is actually caused by a breakdown in the small blue capacitor located...
  10. H

    Ferroli Optima Honeywell VMF7 PCB Relay Fault

    My Ferroli Optima Boiler struggles to ignite due to a buzzing/chattering Relay. Apparently this is a fairly common fault and a new PCB costs about £180. The chattering Relay is the one to the far right of the PCB and often looks burnt due to the sparks caused as it chatters. After much...