    Pump won't stop when cylinder stat set to 60c

    Can't thank you enough. Set boiler to 4, pump to 2. Pump finally shut off! I found an old pipe thermometer which I put on tank next to stat which said 53c on a stat setting of 60c. So one is wrong, but now have enough hot water for two showers or more where as when stat was set at 55c we only...
  2. V

    Pump won't stop when cylinder stat set to 60c

    Pump is a grundfos seletric with settings 1,2&3.
  3. V

    Pump won't stop when cylinder stat set to 60c

    How high shall I set boiler? I have a micro bore CH system and last winter lots of hot drips came into the expansion tank warming the water in it. I have a small cottage w/ 7 rads. CH pipes never been power flushed etc. Pump is set to 3. What do you suggest for boiler setting and pump speed? Thanks.
  4. V

    Pump won't stop when cylinder stat set to 60c

    The boiler is a Potterton Prima F the i in Prima is a 1 with a dot on top like Pr1maF. It's set on 3. It goes from 0 to 5 then max.
  5. V

    Pump won't stop when cylinder stat set to 60c

    Hi all, I hope someone can help. Recently my pump keeps running if cylinder stat set to 60c. If I lower stat to 55c it operates normally. At 60c the boiler shuts off when temp reached but not pump. Pipes to & from cylinder are hot as is valve to cylinder. I thought maybe cylinder stat was at...