Search results

  1. A

    Wireless Video doorbells.

    I have Arlo cameras installed and wanted something that I could use with my existing setup. They have a new doorbell coming shortly. Looks really good. https://www.arlo.com/en-us/products/arlo-doorbell/default.aspx Also a bonus is that there is no ongoing cost!!!
  2. A

    Remote CCTV - web access

    I would look at the Arlo smart home security cameras. I have them and they are excellent. Simple to install and come with free cloud storage and the option of local storage too. Built in alarm, two way audio and night vision and can be used outdoors.
  3. A

    Block and beam floor - height not correct with existing

    Looks as though I may have found a solution - I can install 70mm celotec floor insulation and then use battens to install a plywood floor. I'll probably use 20mm ply to match the existing floor height. Any one got any thoughts?
  4. A

    Block and beam floor - height not correct with existing

    I should have added - I need to find a solution that doesn't require me to replace the blocks and isn't too costly. Having lost £12000 I am struggling to finish the extension. Thanks so far!
  5. A

    Block and beam floor - height not correct with existing

    What are the downsides of using 50mm insulation and 50mm screed?
  6. A

    Block and beam floor - height not correct with existing

    Stressline 125 x 150) pre-stressed ‘I’ concrete floor beams at 530mm centres. Infilled with Grade blocks with a maximum density of 1900 kg/m3 block size 440 x 215 x 100mm. Block to be capable of supporting a 3.5kN transverse load over a 400mm clear span. The extension is 4m x 8m wide.
  7. A

    Block and beam floor - height not correct with existing

    Here are the specs: Suspended concrete floor – ground floor • Floor level to match existing. • 65mm screed including mesh reinforcement. • 1200g D.P.M. Laid under insulation minimum lap 150 mm. • 90mm Kingspan TF70 insulation • 20mm Kingspan TF70 at perimeter walls equal to insulation...
  8. A

    Block and beam floor - height not correct with existing

    Thanks for your help. I am hoping there is a more efficient insulation that I could use so that I don't have to put in 75mm or the floating floor sounds like a plan.
  9. A

    Block and beam floor - height not correct with existing

    New to the forum - so I hope I have posted in the correct section. I currently have a double storey extension being built - previous builder did not complete the job, £12000 lost on unfinished work and now I have new builder completing the job. Problem I have is that the block and beam...
Back