Look gus4778 it doesn`t matter whether or not your board is or isn't big enough or whether or not in some peoples opinion whether it is safe or not. you have had someone ( competent ) look at you board and say that there is a problem with it, I personally would not do any work for you without...
Not having the regs to hand i`m sure that Regulation 314.4 states that if an installation has more than one final circuit then every final circuit must be supplied from or connected to a seperate way in the fuse box.
Hi there . on your new stat
your permenant live - 1
your load live - 2
your neutral - N
without testing you existing wiring i cant say what colour is what, espesialy because your blue is connected to NC.
Normaly it would be
your red permenant live
your...
Sorry but F**K ME that is the messiest fuse box i have ever seen I would definitely let the NICE contractor do what ever he thinks needs doing . I wouldn`t be worried that this guy is going to rip you off, looks like you have been already .
Firstly well done with going with an NICE contractor for your own peace of mind on getting it right this time .
Secondly Is you current fuse box a 16 ed fuse box ? if so is the NICE contractor wanting to change the fuse box to a 17 ed box to provide rcd protection to the modified circuits...
Thanks for all your posts guys . reading every thing i am confident it is the water. going to do the test next week with different water :idea: (will remember the tea bags)
Hi there i belive that on your sun vic
your red is common, 1
your blue is neutral 4
your yellow is demand 3
satisfied 2 not used
green/yellow to earth. hope it helps
Any thoughts?
One of my customers has a new kettle but every time he plugs it in to boil it always switches off before it boilling. He has changed the kettle and the new one does the same.
He changed the kettle for a diffrent make and that does the same .
He has tried the kettle in a...
Hi there, if you are testing the inulation resistance live to earth, neutral to earth, live to neutral or combined live + neutral to earth and in each test getting readings >300Mohm then this is a good result. :)
If the cpc`s are indeed just snipped off in the ceiling rose, don`t just trim them back, use them and assume you have a reliable earth as they may be snipped off in all the light fitting in the circuit you will end up with a class 1 fitting which is not eatrhed . :cry:
very good link makes interesting reading thanks, but as Grid-tie inverters are designed to quickly disconnect from the grid if the utility grid goes down. And is an NEC requirement that in the event of a blackout( as Islanding can be dangerous to utility workers, who may not realize that the...
Cheers for the reply, Its a trickey one, so far each installation i have done i have connected the inverter onto the double pole side of the consumer unit or where there is no room provided a new consumer unit for this reason. When i did the logic course with Grant they wern`t sure either.
I...
Hi, there, just wondered if any one could clarify. With regards to the inverter disconnection. Correct me if i`m wrong - ``the inverter must disconnect the ac supply to the consumer unit within 5 seconds when the mains ac power is lost. The ac supply to the consumer unit from the inverter can...
hi guys, i too have had problems with Lv lamp holders in fire rated fittings, where the customer replaces the lamp with the incorrect lamp, with some fire rated fittings you can only use lamps with aluminium reflectors which throw the heat forward. with the incorrect lamp the heat closes up the...
DONT FORGET THAT CABLES CAN NOT SIT DIRECTLY ON THE PLASTERBOARD CEILING AS THIS IS NOT WITHIN A PRESCRIBED CABLE ZONE SO WHY NOT TRY TO KEEP THE CABLE ABOVE THE INSULATION AND ALWAYS REMEMBER TO USE RCD PROTECTION.