    Water leaking through shower control panel when basin tap turned on?!

    Quickest way to check is turn off all the power at fuse box and retest tap.
  2. U

    Water leaking through shower control panel when basin tap turned on?!

    Maybe a shower pump which is also connected to the basin? Turning on the tap, switches on the pump and increases pressure to the shower, which then leaks? Does it leak when the shower is on too?
  3. U

    Ideal C35 Running Cost

    448 kWh is 1422 cubic feet which could be incorrectly converted / rounded in some way to your 14.3 measurement - it does sound like some kind of conversion / calculation error. What did they say when you gave them the info? For reference, I have a 4 bed detached and we used 419.2 kWh for the...
  4. U

    Pipework from Existing Boiler to New Outbuilding

    F&R is Flow and Return for the heating. Burying the pipes underground will help protect against frost.
  5. U

    Pipework from Existing Boiler to New Outbuilding

    I would price up a few different options; suitable cold water feed; running gas pipe and new system or combi boiler; electric heating; electric vs combi/system shower and also think about how often you think the space will be used in Winter (heating), Summer (showers?) and what kind of...
  6. U

    Boiler Running Continuously

    Micro switches are very easy to test using a multi-meter to verify the fault.
  7. U

    Smart Wireless Thermostat - receiver not hardwired to router

    There are THREE components to those systems, one which sits next to the router and connects via RJ45 cable (Bridge/Hub), one component that connects to all the boiler wires (Receiver) and a third component which attaches to the wall in your hall (Thermostat). So, whilst they only connect via a...
  8. U

    Potterton Combi Low Pressure

    Are you turning BOTH handles on the filling loop? (both sides of the filling loop are currently closed)
  9. U

    Not your standard plumbing question: pipework to plumb in pressure washer?

    You could use a pressure washer extension hose, clipped to the wall? They come in a variety of lengths and connectors.
  10. U

    Excessive Gas Consumption - Not sure what to try next!

    I entered my data into the above and found it came out very similar to the whole house and stelrad surveys I have previously conducted. You just need to enter room and radiator sizes & types. This will give you an indication on how much kW your radiators can disperse vs your boiler output and...
  11. U

    Excessive Gas Consumption - Not sure what to try next!

    Interestingly, I just read on Glowmarkt's site it says "See historical data from when your smart meter was installed." - so if your interested in seeing the usage data from before you moved in (assuming the smart meter was already installed), you may be able to see it ;)
  12. U

    Excessive Gas Consumption - Not sure what to try next!

    If you don't mind another company seeing your usage data, you can sign up to https://www.glowmarkt.com/bright and access your data in graphs, tables or download as a CSV and there is a plugin for Home Assistant too. The data is obtained directly from DCC (the middle man between smart meters and...
  13. U

    Excessive Gas Consumption - Not sure what to try next!

    It’s best to think of HA as a OS, rather than an app. Install on appropriate HW as a OS or in supervisor mode for ebusd. I originally installed on an early PI then moved to a micro PC. HA addons like ebusd, Adguard, Mosquito, Ngnix and others need OS or supervisor mode. HA itself has its own...
  14. U

    Excessive Gas Consumption - Not sure what to try next!

    Supporting Home Assistant is very off topic for this thread, may I suggest you ask for help / look for advice somewhere more appropriate such as https://community.home-assistant.io/ or https://www.diynot.com/diy/forums/home-automation/ ?
  15. U

    Excessive Gas Consumption - Not sure what to try next!

    I posted links to everything I am using above! :)
  16. U

    Excessive Gas Consumption - Not sure what to try next!

    Installation of the adapter itself and HA integration was simple, like yours… It was more there were no config files specifically for my boiler and vSmart thermostat. The VR65 also wasn’t detected at first, it needed the adapter PWM tweaking to be seen on the eBUS. I wish I had the adapter when...
  17. U

    Excessive Gas Consumption - Not sure what to try next!

    Yes, probably best to play around in the summer, ready for next winter! :) - This is the HA ebusd addon I use with the WiFi adapter I posted above, which seems to be reliable (I've had it installed 6+ months and only just got around to playing with it in HA)
  18. U

    Excessive Gas Consumption - Not sure what to try next!

    I also have a eBUS adapter attached to my system, which feeds into Home Assistant using ebusd addon (That's where the graph I posted came from). If you are tech savvy**, HA will almost certainly be your friend when it comes to trying to get Tado and eBUS working together. No idea what's possible...
  19. U

    Excessive Gas Consumption - Not sure what to try next!

    Another thing you can add to your list would be to complete a whole house heat loss survey (there’s maybe better ones than the link, but should be good enough as a starting point) It could be that your boiler is oversized for your property, If the heat loss calc comes out a lot below 30kW...
  20. U

    Excessive Gas Consumption - Not sure what to try next!

    eBUS allows the room control to tell the boiler what temperature it needs, based on current inside and outside temperatures. Weather compensation / flow modulation makes your system more efficient (~10%) vs cycling the boiler on/off (which uses more gas / less efficient) Vaillant controls are...