  1. A

    Vaillant Ecotec 824e F.28 fault

    F.28 could be coming up because your regulator at your meter has had it (this will be fixed free of charge by the gas board, but will need to be identified by a gas man first). Have you tried pressing the re-set button? Also was any work being done in the road on your gas main? F.28 or F.29...
  2. A

    thermastatic shower with 130 centres and 22mm feeds

    Hi guys, Went to a call out the other day to find a thermastatic shower that was leaking and broken. I'm trying to avoid breaking open the wall as it is a nice place and will be imposible to get matching tiles. Thje shower was bought from bath store in 2000 and is believed to be made by...
  3. A

    Cleaning existing system for new boiler

    Thanks, will try that, I don't think it's paticularly dirty or anything just want to make sure no crap gets to the new boiler. i'm fitting a magna clean as well so should be ok. If the pump has had it though surley filling loop open and hose connected should shift i?. Close all but one rad and...
  4. A

    Cleaning existing system for new boiler

    Can you open the filling loop with a hose connected to a drain off to remove sludge ect? i am replacing a boiler tommorow as the old one has totaly gave up (yes i am gas safe) i can't afford a powerflush as i am just starting up and am unable to put cleaner into the old system as the boiler is...
  5. A

    boiler not firing,return blocked???

    Are you On a 1 pipe system? (are the flow and return picked up from the same pipe)
  6. A

    3/4" pipe and 22mm - will it work?

    is the drip near the taps?
  7. A

    anyone got work from "myhammer"?

    Hi, i was looking at the myhammer site and was wondering if anyone can tell me what happens and if it's any good. I am trying to start up on my own and i could use all the help i can get.
  8. A

    worcester 30si

    I wasn't sure but was told by 1 guy at a local plumbing supplies place that I should fit this boiler, to be told by his work mate that it wasn't man enough. I have gave them a price for an ideal pro logic+ as well now this give 14-16 litres per min so seems a better choice as they get a 5 year...
  9. A

    worcester 30si

    will a worcester 30si be able to keep up supply to a 4 bed house with 2 bathrooms?
  10. A

    How to add inhibitor

    I need to put inhibitor into a pressurised system but the rads are the rolled top ones (no removable vent) any tips????
  11. A

    central heating nightmare

    I was told to attatch pump, release presure through prv, keep it open and pump until vessel reaches and holds charge. Is this the correct way?
  12. A

    Potterton Combi 80 occasional overheat/lockout

    sounds like the a problem with the automatic bypass.
  13. A

    boiler not firing,return blocked???

    What did the guy do to decide there was a blockage on the return? The fact that it is not fireing and you have no hot water sugests to me that that is not the case.
  14. A

    cleaning / de-scaling heat exchangers

    any advice on cleaning / de-scaling heat exchangers? Any advice on removing them?
  15. A

    Viessmann vs Intergas vs Atag

    They come with a 3 year off the shelf gaurentee anyway.
  16. A

    Viessmann vs Intergas vs Atag

    Intergas boilers, have a great heat exchanger (22mm heating 12mm hot water) so the chance of it getting clogged up is low (intergas claim they have never had a problem with one of there heat exchangers and give a 10 year gaurentee for them) however if ihibitor is fitted you shoildn't get sludge...
  17. A

    central heating nightmare

    If you have water coming out i'd say the diaphram had split so it will need replacing.
  18. A

    Worcester 24i intermittent hot water

    excelent, I only have my number at the momment though as i only got that last week (via e.mail) still waiting for my card so i guess this will have the info needed
  19. A

    Worcester 24i intermittent hot water

    Thanks for your help bengasman, I aplied to join the gsr engineer forum earlier. Just waitin to be allowed (guess my gs number has to be checked 1'st) only joined this site 2day seems like it could be a helpful site though.