  1. mcmoby69

    Gas meter in garage - issues.

    I suppose saving a few quid is worth more than your kid's lives if anything were to go wrong........ probably won't get your house re built on the insurance either. Just saying.
  2. mcmoby69

    Is my expansion vessel too small?

    Installed in 2011. Ever had it serviced?
  3. mcmoby69

    Auto air vent failure Worcester combi

    £800? Size of house and amount of rads? Get 3 quotes. Consider getting a filter fitted
  4. mcmoby69

    Way to stop upstairs neighbours flooding my garden?

    Land registry will tell you who owns the property. Will cost you £13 ish Or try a Google for rental property, it may give you letting agent details. Contact them and ask the landlord to deal with it Problem is, tenants may get arsey and act worse. Environmental health might be interested but...
  5. mcmoby69

    Unusually water leak on a Worcester Greenstar 25cdi boiler. The plastic section behind the dhw temperature sensor has developed a slow leak.

    Nothing unusual about that part leaking, quite common. Usually because the boiler has been installed without a shock arrestor. Relatively easy job. Might be a good idea to do the right hand block too, with a new flow adaptor and silencers. Not as cheap or as easy, and fit a shock arrestor too.
  6. mcmoby69

    Possible Airlock

    Google primatic cylinder. Evident by lack of separate f&e tank for central heating. Ie one big tank feeding cylinder only.
  7. mcmoby69

    Vaillant boiler help

    You never mentioned the salus controller or stat you have fitted. A please or thank you appears to be missing from your posts too. No wonder I don't venture in here often.........
  8. mcmoby69

    Hot water not hitting top temperatures

    All of the showers will have nrv's built in. If they are bar showers it's easy to find which are passing. Run the shower on fully hot, feel the left inlet pipe (usually hot feed) it will get hot. Turn shower off. If the nrv is faulty it will go cold pretty quick. Repeat with all of them.
  9. mcmoby69

    Hot water not hitting top temperatures

    It could be tmv's installed have a non return valve stuck open, causing cold mains water to push through into the hot supply back to the calorifiers. Won't be noticeable during the day with everything being used. Only when demand stops. Had similar in a pathology lab where storage tank would...
  10. mcmoby69

    A lot of water coming from the overflow pipe and the boiler vibrating a lot

    ring a boiler man, filling loop connected and passing or plate heat exchanger has failed. probably needs a new prv now as well.
  11. mcmoby69

    Need help with Radiators cold at Bottom - not sludge

    Can't see any mention of what types of rads you have , t11's t21's t22's or designer rads etc? How many metres of 22mm out of the boiler before it reduces to 15mm?
  12. mcmoby69

    Gas fire isolation

    always hated restrictor elbows and the pipe on view to the fire. always tried to hide them. restrictor elbows serve a purpose and the associated pipe work is more robust than copper weaving its way over the hearth etc, plus it looks like it belongs there. its the way it used be done. personally...
  13. mcmoby69

    How to turn off Glow worm preheat

    not that familiar with GW tbh, only done a couple. I would assume that there is a parameter that tells the boiler 'what type it is' system or combi etc. therefore dhw preheat wouldnt come up in parameters as a choice if it was told it is a system boiler? Ive done it myself, was on the phone to...
  14. mcmoby69

    Need help with Radiators cold at Bottom - not sludge

    your boiler can provide up to 24 kw for heating rooms. my general fag packet calcs say thats enough for a 12 room house. keeping the flow temp down is good as is adjusting pump speed to make sure it gets round all the system. have you range rated the boiler? parameter 3 needs to be set...
  15. mcmoby69

    Does this sound like delayed ignition?

    its struggling to light, bad gas mix, low gas pressure, blocked condensate all possible causes. might be a sticky governor on the gas meter. you need your installer back.
  16. mcmoby69

    How to turn off Glow worm preheat

    installer has possibly not removed the factory installed link when installing the thermostat.
  17. mcmoby69

    britony combi 80se burner goes on and off

    Council plumber equals Council flat. 2002? New boiler.
  18. mcmoby69

    Condensate boiler in garage

    Doesn't your rgi know this? Asking for a friend....
  19. mcmoby69

    Atag Efficiency

    Feel each radiator at the bottom in the middle. Any cold spots, rad is blocked. How long was he there for?
  20. mcmoby69

    Atag Efficiency

    Did your installer flush the existing pipework and radiators? If not it could be that your boiler return temp is too warm which the boiler senses and assumes that the heating is warm enough, and, shuts the burner off. They monitor everything electronically and adjust burners, fan speed and pump...