  1. R

    ravenheat csi 85 combi leak,

    Hi looking for some advise on a part no for the above boiler,Its leaking on a joint which comes from the heat ex up to the auto air vent looks like poss black rubber seal sits in the heat ex outlet, then 15mm pipe sits in that and goes to air vent . any advise would be gratefuly appreciated...
  2. R

    dimplex epx750 wont stay on

    Hi looking for some advise on these heaters ,don't know to throw away or get fixed.When you have them on manual the light is on on the top when you press to turn the heater on it switches its self back to standby . Can anyone advise of possible problem Thanks Mark.
  3. R

    c&m se combi 80

    1.Hi looking for some advise, boiler diagnostic is flashing, fan on but does not activate air pressure switch. But the fan is not running or no power to it 2. removed tubes to air pressure switch. now showing fan off but air pressure switch fails to return to off position, Any advise would...
  4. R

    bristan oval shower

    Hi am looking for some help please. With a bristan oval thermostatic wall flush shower, only getting 40 deg when on hottest setting ,boiler hotwater set to max .Can anyone advise of a parts stockist or possible fix. Thanks mark
  5. R

    c&m se combi 80

    HI looking for some help on a part number or a web page with the info on so i can look it up.Have dropped a clanger, ordered a part off sabre, a pressure sensor part number 61003495 never gave it a thought they had changed the part from a push in sensor held in with a clip to a screw in one...
  6. R

    boiler mate 2000 problems quote for works

    hi was hoping for a engineer to advise or quote for the following problem may be thermister or plate to plate would be very grateful of any input but hopefuly a engineer to carry out works getting hot water 20 sec then cold then warm then cold has anyone got any knowlage on the above in the...
  7. R

    vaillant 828/2e

    hi was hoping somebody could give some advice on a vaillant 828/2e . when on hot water boiler making a eeeerrrrrrrrrrrr noise when water on full. thanks mark
  8. R

    water coming up from shower drain

    Hi was looking for some advise please . Have got a flat on the third floor and in the last week dirty brown water has started to come up out of the shower drain to almost fill the tray. am guessing there is a blockage some where but was wondering where best to start
  9. R

    stolen cable

    HI after some advise new build flats (42) 3 incoming pme supplies . vandles have broke into 3 plant rooms and stole the earth cable .does anyone know if scottish power will charge for the incoming earth cable that has been hacked of just below floor level in the duct .am not an electrician...
  10. R

    baxi 133he plus

    Hi, Was hoping for some advice on a baxi 133he plus. 1.pressure vessel has failed 2. there is a leak from the back of the plate to plate or may be diverter. 3. only fires up for h/w not c/h 4.when water is on makes a loud noise not sure if its the fan or a blocked plate to plate...
  11. R

    ravenheat csi 85 combi

    forgot to ask has anybody got any ideas please?.
  12. R

    ravenheat csi 85 condense

    h/w but no c/h divirter moving