    Help choosing PIR for full glass conservory with alot of sun

    what would be good position. I am assuming not facing towards the front glass or direct sunlight? Also I want to mount it on a wall which just has a fence but worried next door moving around will pick up from behind sensor ?? is that possible on the microwave on this as I know it is on other...
  2. J

    Help choosing PIR for full glass conservory with alot of sun

    Hello, I would like to install a pir for a conservory which does get hot in summer time at 43 degrees and morning sun hit it hard. the place is 6 m long by 5m and had a african grey parrot in it. can anyone help choose one. As I have use dual pir microwave and pir in other places and still...
  3. J

    honeywell g2-g20 bell box and zone lock out.

    It was on max because the min level was so sensitive and thought they got it wrong lol. But on max the level is the same as the min level. btw the sensor is new and i got more of the them in the lost just. Just wondering its to sensitive as the room is to small maybe
  4. J

    honeywell g2-g20 bell box and zone lock out.

    Ok i have finished the wiring as you can see in the picture. Everything works fine. But I am a bit confused why the it show nothing in the menu under RIO yet picks all the zones up and psu is fine as well. Also why is the voltage different from both boxes. G2-20 is 13.7v yet the powered RIO is...
  5. J

    honeywell g2-g20 bell box and zone lock out.

    i am using pa o/p 4 from power RIO to dialer to trig A dialer input. This this mean i need to remover the pull up from the RIO because to me it looks like you talking about outputs from from dialer to box as thats the only open collector on the dialer. g2 i am using 1001 to trig b to dialer...
  6. J

    honeywell g2-g20 bell box and zone lock out.

    Hi I have started installing my powered RIO and i am a electronic engineer and i abit confused on this the g2 power is 0.5a mains and powered RIO is 1A mains so total is 1.5A. Both box are next to each other. I want connect both box to the same fused spur. powered RIO states only one mains...
  7. J

    SKY Dish signal help

    unscrew the f connector and check if the center pin is not broken and do you have a multimeter
  8. J

    SKY Dish signal help

    go into the sky box setting and check signal strength
  9. J

    honeywell g2-g20 bell box and zone lock out.

    Thanks for that. Why have they not written this in the manual or the documents? I gone through all of them and it only says to connect the bus like. Just hand it stupid they not written something important like this. Thanks for the information i will be installing his panel in two days just...
  10. J

    honeywell g2-g20 bell box and zone lock out.

    Also why does the p026 have a connection called bell box connector at 14.5v what is that used for when the voltage is 12v for everything and the bell box outside. So why is this one 14.5v?
  11. J

    honeywell g2-g20 bell box and zone lock out.

    hi where do i connect the 0v from the control panel to the rio power controller. Looking at the diagram i am guessing it connects just after the fault op connector next to where the zone connectors are labeled 0v?
  12. J

    honeywell g2-g20 bell box and zone lock out.

    hello does anyone know if i can charge the back up battery on the power rio because i have just connected the power to panel and then battery but dont get 12v output from batt connection to charge battery. they are low and need charging
  13. J

    honeywell g2-g20 bell box and zone lock out.

    09=Set (Reflex) The Set output is activated when the assigned groups on the system are set. This output is a Reflex output and follows the set and unset status of the groups. As this mode is reflex and not pulse i guess there is no other function i can use to do what i want.
  14. J

    honeywell g2-g20 bell box and zone lock out.

    ok the tried a few settings regarding my buzzer in the porch that i want to use a beep to let me know the all has been set in full mode. when i set the buzzer function to "set" the buzzer is always on in full set mode when i set the buzzer function on "unset" the buzzer beeps 2 twice and turns...
  15. J

    honeywell g2-g20 bell box and zone lock out.

    oh I was not aware that i would get full keypad control of the keypad. i thought it was just to let you know
  16. J

    honeywell g2-g20 bell box and zone lock out.

    https://ipautodialer.com/ has anyone used this before ?
  17. J

    honeywell g2-g20 bell box and zone lock out.

    Hi When i set the alarm on full set and leave the house i cannot hire the double beep because i have a porch and keypad is next to second door inside house. I have the volume set to 00 on the keypad as it so loud. Yes in can increase the volume behind the keypad which i think means i can hear...
  18. J

    honeywell g2-g20 bell box and zone lock out.

    Hi Thanks for the advise. How come 0V needs to be connected from control panel if it has its own power? I understand the bus lines connected for coms. I dont have space for the bigger box. So I guess i have to put it somewhere else in the loft. So i need to also buy another battery as first...
  19. J

    honeywell g2-g20 bell box and zone lock out.

    so i did a rough power consumption below as my f2 current is reading 480ma on standby mode where a fuse of 500ma suppose to be. 8 pir = 80ma (assuming each one is 10ma) Impaq Shock Sensors (4) = 50ma Rio box = 40ma sd1 dialer...
  20. J

    honeywell g2-g20 bell box and zone lock out.

    ok i had a read of the manual again even though i read it yesterday. So my understanding is "confirm time" of 30 mins i had is when the alarm would rearm and omit that zone. my bell time was on 15mins meaning if that zone was triggered again after 15mins the bell box will be on for another...