Search results

  1. S

    Laying gravel on paving stones

    We have used this technique on a few contracts and found it more time efficient than the traditional monoblock paving. on a small pathway i think it would be reletively easy and cost effective. the templates or stamps can be bought on ebay for about £30-£50 (delivery can be expensive as much...
  2. S

    Laying gravel on paving stones

    If i get what you mean correctley, Stone on top of a concrete path can be done, but i think you would be better to repave on top of the existing path. i have stones on my drive and although they look ok, i am not a fan. i have actually seen a new product where you just take concrete and clolour...
  3. S

    Whirlpool ADG 7560/1 Dishwasher Fault

    I have a diplomat dishwasher that is made by whirlpool and i have a list of all the fault codes and none come up as 16 flashes. it is usually 1 - 9 flashes. can you check again?
  4. S

    Tumble dryer issue

    I have had a similar problem with a hoover tumble dryer. first thing to do if it's a condensing dryer is to remove the condensing element and make sure it's clean. I did this to mine and it was covered with fluff. i now do this evey few months as it keeps it working more efficiently. if...
  5. S

    Diplomat Dishwasher F7 error

    OK so the valve does not seem to be working. Also had my dad who used to be an armiture winder many years ago checked the fill chamber and he said that he could not get any signals from it no matter what he did. so looks like i will need to replace both parts. I can't seem to find the inlet...
  6. S

    Diplomat Dishwasher F7 error

    Checked the pressure switch and it is OK. It was full of crud so i cleaned it out. Went round and checked all the connections and all were secure. turned it on and got an F6. going to try and wire up the valve at the weekend and will keep you posted.
  7. S

    Diplomat Dishwasher F7 error

    Thanks for the advice it's much appreciated. A wee question, how do i hot wire the valve? and as for the pressure switch i can get hold of a multimeter, but for testing the pressure switch what do i do. I'm not an electrical engineer so any direction would be appreciated.
  8. S

    Diplomat Dishwasher F7 error

    Hi I have misread the model number it is an ADP 8322, and the number is 854500015810.
  9. S

    Diplomat Dishwasher F7 error

    Hi, i don't think it's a Smeg i was told before it was a Whirlpool machine, but i'll check the door sticker later today.
  10. S

    Diplomat Dishwasher F7 error

    I have a diplomat dishwasher ADP 8132 and it is giving me a F7 fault, so following notes on a previous post in this forum, i have removed the side pannels and removed the plug on the fill chamber and cleaned the terminals on the plug connection. I also checked all the plugs and mountings inside...
  11. S

    DiplomAt dishwasher - ADp8132

    Hi I have a diplomat dishwasher ADP 8132 (i think) and it is giving me a F7 fault, so following notes on a previous post in this forum and cleaned the terminals on the plug connection at the front left (can't remeber what it's called), and also checked all the plugs and mountings inside the...
  12. S

    Sime Digital Format boiler cutting out

    Also checked with the building control for my council and they have said that all they require is the gas work to be done by a competent person. and as for the gas certificate, the installer is going to get this done for me. Thanks again for all the advice.
  13. S

    Sime Digital Format boiler cutting out

    All, Thanks for the advice on this one, for your info the installer has come back a few times and has finally found the problem. The system still had some gunk in the system and it was blocking the heat exchanger in the boiler, which in turn was cutting out when it got too hot. the system...
  14. S

    Sime Digital Format boiler cutting out

    That explains a lot. he did say that when he has completed the job, that Scottish gas should come out to do a first vist and get it onto my homecare agreement. Thanks for the Info.
  15. S

    Sime Digital Format boiler cutting out

    Tony, No I'm not paying him. The problem is that he did the instal as a home job, and when he is trying to sort the problem the Sime lines are closed. Yes he is Gas Safe Registered, but is relativley young (early 20's).
  16. S

    Sime Digital Format boiler cutting out

    The engineer came round on Friday and spent three hours trying to find the problem, then again on Sunday for four hours. He spent the whole time going through each part, starting with the flue, pump, hot water divert valve, and also looking at the settings. he had no luck in finding the problem...
  17. S

    Our Central Heating has our plumber stumped...NEED your help

    Thanks, i have started my own thread.
  18. S

    Our Central Heating has our plumber stumped...NEED your help

    Hi I have a similar problem with my boiler. the engineer installed it two weeks ago, and all worked fine. But now the heating works perfectly but when we switch the water on it heats up to temp then cuts off. It's a Sime digital format, and the engineer has been out three times, and worked on...
  19. S

    Sime Digital Format boiler cutting out

    I have just had a new Sime digital formet boiler fitted a few weeks back. all was working perfect until 4 days after install and the hot water stopped working. I am still waiting on the clock to be fitted, so was operating using the on off switch next to the temp indicator. The heating is...
Back