    Valiant ecotec Pro F.73

    I found it was the pressure senser return cable open circuit. When I 'cleaned' the temp sensor the first time I must have moved the cable and that's why it worked (not me cleaning the sensor). I have just replaced the cable and the bioler started up first time. Don't know how it went open...
  2. M

    Valiant ecotec Pro F.73

    I've just metered accross the green signal return cable of the water pressure switch and unbelievably I think it's open circuit. I'm getting 5v supply to sensor but nothing back on PCB from green signal cable. However, if I meter at sensor itself, green cable shows 2.5v. Going to double check...
  3. M

    Valiant ecotec Pro F.73

    I replaced the old black sensor 0020016532 with a new black one 0020014190. I read that this was the replacement part for the old Glow worm part.
  4. M

    Valiant ecotec Pro F.73

    Hi, thanks for the response. I have already replaced the water pressure sensor. What is the 'communication drilling'?
  5. M

    Valiant ecotec Pro F.73

    This is the -bar display when I press the - button.
  6. Untitled

    Untitled

  7. erorrs

    erorrs

  8. M

    Valiant ecotec Pro F.73

    Hi, I have been having an issue with my valiant boiler which is approx. 4 years old. Last week I got the F.73 fault (water pressure sensor) but the manometer read 1.5 bar and the EV seemed to be correct pressure. I read on these forums that sometimes cleaning the pressure sensor would...