Search results

  1. Billb47

    bathroom Fan

    No, I got 2 10mm into the spurbox, from the spurbox to the pull switch I used 1.5 T/E and from the switch to the fan. So the power supply to the fan had a 5 amp fuse to cover it. If some thing went wrong with the fan it would blow the 5 amp fuse and trip the main rcb. I'm not that stupid as to...
  2. Billb47

    bathroom Fan

    I ran a 10mm cable from the shower switch to a spurbox with a 5 amp fuse, from that I used 1.5 T/E from the spurbox to a pull switch to the ceiling fan.
  3. Billb47

    bathroom Fan

    That's true. Lol. Thanks anyway.
  4. Billb47

    bathroom Fan

    Thanks for the help, much appreciated. It was just a query that's all. I'd fitted a new consumer unit a few months ago. Had a qualified electrician in to pass it off when he noticed how I'd got the fan and shower hooked up. He said it can't be done like that and that it should have its own...
  5. Billb47

    Strange 'tamper proof' retaining screw on UAP euro cylinder

    Alarm, Obviously I missed it. Sorry to step on your toes
  6. Billb47

    Strange 'tamper proof' retaining screw on UAP euro cylinder

    Hi Kevtom, I have come across these before, you could try to use a screw extactor that looks like a drill bit but it grips in reverse. Also you could try tapping it round with narrow puch and a hammer and give it slight taps till its out far enough to get pliers on it. the only other problem...
  7. Billb47

    repairing double glazing

    Its your sealed units that have broken down, you dont have to replace your windows. If you go on google and type in sealed unit replacement london, you can find loads of companies that can help you. If they try to sell you new windows tell them politely to bog off.
  8. Billb47

    plastic back door

    Hi David, Plastic or wooden, you have to look at it this way, if a burgular wants to get in he will. normally it will be through a window not a door. most upvc doors these days have 5 point locking, 2 leavers that are hooked go up and 2 go down then you have a dead bolt in the middle thats...
  9. Billb47

    uPVC sliding doors too small for frame and fall out !

    Hi Arambol, From the look of you photo it looks like the sealed units have come out and not the frames, At the bottom of the sash that opens, there should be a hole roughly about 13/15 mm round. if you look inside that hole you will see an adjusting screw( normally pozy drive) if you turn it...
  10. Billb47

    bathroom Fan

    Thanks for the reply sparkwright, I did have it spured of the shower switch going through a 5 amp fuse box so it only came on when we used the shower. Since then the electric shower got that furred up with lime scale that i took it out and put a thermostatic shower in, instead of another...
  11. Billb47

    measuring up for a replacement sash window

    there is another way of doing this, if the timber suround is sound, you could take out the sashes and fit a upvc window in between and leave the sash boxes inplace.Then you can either plater board them or cover with trim. I know from past experiance, taking out a sash window is a messy job.
  12. Billb47

    Window configeration advice

    It is possible to do, but you will have to know what profile you window is, you can get whats known as a mechanicle joint which screws into you existing frame. then you will have to determin what size casement you want. Most window manufactures wont weld a casement under 230mm in hight. It...
  13. Billb47

    bathroom Fan

    Thanks for the reply, I dont want the fan to come on with the lights, I want it switched separately. As I understood i thought that you would only need an out side isolater if it was a electric shower, which this is not. I'm bringing the 1.5 cable from the fuse bored which is a 6amp trip switch...
  14. Billb47

    Tilt and Slide Patio door lock

    Hi Bettie, I used to be a window installer and have been for 25 years, i worked as an installer and a service engineer. so if i can help i can.
  15. Billb47

    Tilt and Slide Patio door lock

    On the handle you will find 2 screws, if you undo them the handle will come off. You will find the spindle, which is a bout 6mm square if this is warn then you can replace it. To open the door you can put a flat bladed screw driver in the hole were the spindle came out. very rare that the...
  16. Billb47

    bathroom Fan

    Hi Guys, I'm new to this site, so be gentle with me.lol Question, I would like to fit an electrical ceiling fan in the bathroom, there is a shower in there but it is a thermostatic one that runs of the combi. Can I run a 1.5 t/e from the mcb to a pull switch in the bathroom and then to the fan...