Search results

  1. E

    Ferroli Falcon II - no hot water

    For the benefit of anyone searching for a similar fault in future, as I had no replies I went with my instinct and replaced the flow meter. Problem solved. Ed.
  2. E

    Ferroli Falcon II - no hot water

    Hi, I have no hot water from my Ferroli Falcon II combi. CH works fine, and water (cold) flows ok from the hot taps. I recently changed the temperature thermistors for both CH and DHW (as I had a problem with CH at the time), so have kinda ruled this out as a potential cause of the...
  3. E

    Ferroli Falcon 2 - central heating constantly runs

    Just wanted to update to say I changed the primary thermistor as suggested and boiler working perfectly again. Thanks to picasso for the advice. Ed.
  4. E

    Ferroli Falcon 2 - central heating constantly runs

    Thanks for the suggestions. The thermister has failed before (only fault I've had with the boiler), so it would make sense for it to have gone again as it has been a few years now. When it failed previously the boiler wouldn't stay running (so indicating up to temp I guess), but the frost...
  5. E

    Ferroli Falcon 2 - central heating constantly runs

    Hi, Recently, the central heating has started constantly running on my boiler when it is switched on, regardless of whether there is a call for heat. I normally leave the boiler on constant, and control using a room stat. I've ruled out the room stat as being a problem - and in fact the...
Back