  1. cornishgas

    One Pipe System

    BTW, that 5-mile radius is pretty much true and it's a semi-circle as he lives on the coast!
  2. cornishgas

    House manily pipes in copper with a tiny bit of plastic

    If you use Hep2O you only have to take it to 10 bar. If I use it I generally have far more copper joints on the system and never unduly worry about that if its a first fix.
  3. cornishgas

    House manily pipes in copper with a tiny bit of plastic

    Not so, the following is from their website... First carry out a low pressure water test at 0.5 - 1 bar when the system is just demountable fittings, then a pressure test at 1.5 x the normal working pressure with a recommended minimum of 10 bar for a minimum of 45 mins. However if any of our...
  4. cornishgas

    House manily pipes in copper with a tiny bit of plastic

    I use Hep and take it to 1.5x working pressure for a while then up to 10bar.
  5. cornishgas

    One Pipe System

    Thanks Agile, I'll try that way first, sounds a lot easier! This seems to be installed the traditional way but it's getting pumped from a newish combi!
  6. cornishgas

    One Pipe System

    Converting to two pipe is last case scenario. The feed to the downstairs rad comes down the corner of the room in 15mm. So if I replace that by extending the one pipe down that corner in 22mm (same as existing one pipe) and loop back up then tee off to the new rad from that, which will be about...
  7. cornishgas

    Riello Oil boiler problem?

    You need an oil pressure gauge to check the pump is running freely and stable, then set the pressure to the correct setting and then put a flue gas analyser on it to get the correct CO2. The boiler if not set up correctly can produce excess carbon monoxide and be a death trap. Get someone in and...
  8. cornishgas

    Remove Danfoss thermo valve

    If it's an airlock try turning off all the other rads except the one you want to get warm, the air should blow through.
  9. cornishgas

    Remove Danfoss thermo valve

    And leave it on full, like in the picture, when putting it on/off.
  10. cornishgas

    Remove Danfoss thermo valve

    Pull all the plastic off all the metal. You'll need to twist it (over not round) and be a little assertive with it.
  11. cornishgas

    Riello Oil boiler problem?

    Get someone in who knows what they're doing.
  12. cornishgas

    Remove Danfoss thermo valve

    Just pull it off. It will expose a pin that the head pushes up and down to control the heat. It's this pin being stuck up or down that is a common cause of rads being permenantly on or off. If it's stuck give it a spray with some GT85 or similar and a gentle tap to free it up. Don't pull on the...
  13. cornishgas

    One Pipe System

    Hi all, fitted a new rad on the ground floor of a small house with a worser bodge combi. Pipe work running from the room above. There was already a loose board upstairs which I lifted and teed into "flow & return", filled up and everything was pretty as a picture until I fired her up... No heat...
  14. cornishgas

    Grandee Combi Oil Boiler

    I realise this is after the event but for anyone that picks up this thread the Grandee combis I've seen continuously pump through the plate heat exchanger to ensure there is hot water on demand because there is no slave tank. There is no voltage to the flow switch on hot water only but there is...
  15. cornishgas

    Gravity Hot Water

    Thanks Ian & Dan, I'll have to put some sort of bypass past the check valve to enable the pump to be reversed but I'll give it a try after checking for a blockage on the tee. I was thinking it might be a new cylinder with gravity coil but its going to be a difficult sell. I drained down to put a...
  16. cornishgas

    Gravity Hot Water

    Help, I have a problem getting gravity circulation going through an indirect cylinder. Rayburn LPG, pumped central heating with check valve on CH flow and pump on return, f&e feed taps into top of return at cylinder, expansion into top of flow at cylinder. Have tried to kettle system, back fill...