    Faulty TRV??

    Sorry to keeping going on about this one but Ive calculated that the total heat loss of 673W (fabric heat loss 320W and ventilation heat loss 352W) so the radiator provided is not under sized as it is 1051W. If the radiator is switching off before the room has reached the set temperature is...
  2. A

    Faulty TRV??

    Thanks for the input. The only thing is the boiler isn't switching off as the other radiators in the house are staying on. Its only the new one that is switching itself off adter a short period. Thoughts? I have the plumber that fitted it coming to see it tomorrow morning - What exactly...
  3. A

    Faulty TRV??

    If by set to the full amount you mean turned up full then yes it is. It may indeed be teed off the main flow as the main feed to the hall radiator was exposed when opening up the wall to create the doorway and the feed was taken from there. So does it sound like it's likely that its all...
  4. A

    Faulty TRV??

    It is undersized!! Would an undersized radiator effect the symptoms I've described - with the radiators getting hot but not staying hot?
  5. A

    Faulty TRV??

    No the room does not get hot enough, it turns off before it reached the correct temperature. As an aside, I think the radiator may also be undersized which I'll need to argue with the builder over.
  6. A

    Faulty TRV??

    the radiator itself also gets hot, it just doesn't stay hot.
  7. A

    Faulty TRV??

    10 radiators, including the new one. New radiator is single 1200mmx500mm, pipe is 10mm and gets hot and yes i can move the pin (although not that easily)
  8. A

    Faulty TRV??

    I have a combi boiler - Ideal Isar. What's the best plan then?
  9. A

    Faulty TRV??

    Hi - I've recently had my integral garage converted into a habitable room and the radiator that was fitted has been supplied from the hallway radiator that doesn't have a TRV, but as I understand it is controlled from the thermostat which is also in the hallway. My issue is that the new radiator...