    Mira Orbis Shower Fault - can any one help?

    Update to this thread. I have now replaced the control board which fixed the problem. :) Thanks to seco services for all the help.
  2. S

    Mira Orbis Shower Fault - can any one help?

    Yes, I know you did - I should have taken your advise. However I had two other people's opinions suggesting it was the relay board which is why I went for that one in the end. Never mind.
  3. S

    Mira Orbis Shower Fault - can any one help?

    Oh well, after getting 2 further opinions I decided to replace the relay PCB, only to find that this made no difference at all. :( So now I'm looking at replacing the control PCB, but I am hesitating because this is getting rather expensive. Mira have suggested I may have had a power...
  4. S

    Mira Orbis Shower Fault - can any one help?

    Thanks very much for you help with this. I will definitely write back here to let you know the outcome, what ever that might be!
  5. S

    Mira Orbis Shower Fault - can any one help?

    Sorry, should have added: The LCD backlight comes on when power is supplied to the shower - it stays on, and does not flash on and off. Only when the shower starts does the backlight flash on and off. Thanks
  6. S

    Mira Orbis Shower Fault - can any one help?

    The LCD backlight comes on when power is supplied to the shower. When I press the large silver on/off button in the middle of the temp control the shower starts. At this point the LCD backlight flashes on and off continuously and the term 'Temp Limit' is shown in the LCD. The temperature in...
  7. S

    Mira Orbis Shower Fault - can any one help?

    The relays are black and opaque so I can't tell by looking if they are moving. However I can tell that if I put the multimeter across each relay that no power is passed from either of them to either element when I switch the shower on. I've tested this on low, medium and high. Sorry I should...
  8. S

    Mira Orbis Shower Fault - can any one help?

    Hi There are two electronic switches/relays on the pcb. Mains leaves the thermal switch and goes into both switches. Each switch controls the mains power to each of the 2 heating elements. So what I've done is: With the shower on checked to see if 240v was across each switch. The...
  9. S

    Mira Orbis Shower Fault - can any one help?

    Hi I can't see a neon on, but I know there is a 'Low Flow' indicator on the LCD which is not being shown. Yes, the water stays cold even on the high setting and turned up into the red. Many thanks.
  10. S

    Mira Orbis Shower Fault - can any one help?

    Hi, Thanks so much for your response. I've put a multi meter across the thermal switch as you suggested. I got a reading indicating continuity which I guess is bad in the sense that the switch is working ok? Any other ideas what could be causing the problem? Many thanks.
  11. S

    Mira Orbis Shower Fault - can any one help?

    Hi I have had a Mira Orbis Electric Shower for the last 4 years which has worked fine with no problems until a few days ago. I noticed that our consumer unit RCD had tripped for all the circuits in the house. Upon resetting it and trying to have a shower the next day I noticed E1 flashing...