  1. T

    Gas boiler KW question

    Take care mate join you soon!!
  2. T

    Gas boiler KW question

    I have left my license card in my assessment room. Ill sort next week. Regards and hope you understand stoichiometric combustion.
  3. T

    Gas boiler KW question

    Pressure loss is measured at the appliance inlet and meter test point recording readings on a U gaug. The pressure at meter may be lets say 21mb then the pressure at the appliance should be no lower than 20mb. S Some boiler manufacturers allow a lower figure but this figure must be used with...
  4. T

    Gas boiler KW question

    Just joined forum so apologies for late response but i don't like incorrect answers. 18-21kw would indicate the appliance is range rated to operate between 18-21kw. This means the engineer would determine what he wanted the appliance to be set at based on how many bathrooms/rads floors and...