  1. G

    Honeywell RSS Update Patch

    I'll PM you
  2. G

    honeywell galaxy wireless smoke detector

    It will be picked up by both systems. The smoke detector transmits supervision and trigger signals along with its serial number. The panel picks up the transmissions and matches them against the programmed serial number to determine if the device has been configured to the system. If not, the...
  3. G

    honeywell galaxy wireless smoke detector

    Yes, they're one way, so just program them on to each panel. Each panel will report when it receives the same signal.
  4. G

    Backlight on Honeywell MK8 Keypad

    It's likely faulty as the LEDs are on the same circuit, so can't be controlled individually.
  5. G

    Alarm box and sounder sound twice on set

    Sounds like you have the external siren set to horn and not bell. That's not a default. The new firmware doesn't have any different defaults, so it sounds like configuration error.
  6. G

    Honeywell Galaxy Dimension 96 and RF Portal issues

    Yes, update to V7.04 either via SPI key loaded with the firmware or via serial RS232 lead and Windows flash program.
  7. G

    Honeywell Galaxy Dimension 96 and RF Portal issues

    What's the firmware version on your panel? The RF portal was only supported at version 6.50 and above.
  8. G

    Galaxy flex entry or exit zone

    Yes, use exit - unless you use part set and the same PIR is first to trigger in the morning. If that's the case use part entry.
  9. G

    Galaxy flex aux tamper 004

    Ok, it may be that you have made a change in error. The tamper is caused by the siren output setting 51.81. Change it from siren to Relay.
  10. G

    Galaxy flex aux tamper 004

    If you used RSS, you didn't perform a full copy before then making a change and overwriting. Did you use RSS?
  11. G

    Compatibility DO8EZS - DO8EZ on Galaxy G2-44+?

    I'm unsure if the ZS sensors are polling less. The V2/Alpha setting is from the sensors themselves, and the portal is supporting both. I'm pretty sure the door contacts only support V2 anyway. I think the old firmware on G2 series is a bit different than Flex. I need to check if changes were...
  12. G

    Compatibility DO8EZS - DO8EZ on Galaxy G2-44+?

    Software for the ez version. The hardware is the same as the do8M
  13. G

    Compatibility DO8EZS - DO8EZ on Galaxy G2-44+?

    The 8Z was released for the evohome. It doesn't support tamper, as it was designed for the heating system to know when a window or door is open. It's the same functionality and frequency wise other than that, so can be used in domestic installs with the Galaxy range and C079 portals. The 8ZS was...
  14. G

    ADT Honeywell galaxy 2.12 comms fault message

    The galaxy panels can't be locked, so just reset the eng and master codes. There are also options to switch alarm reporting to a low cost IP based method by adding a low cost module like the SelfMon VMOD (LCE-K3). I've sent a PM with more details. Disclosure: I run SelfMon. There's also a...
  15. G

    ADEMCO MICROTECH GALAXY 8 PLUS CP171

    That's because the panel is configured for remote reset. On the 16+ panel, when in engineering programming mode, select 06 - Parameters, 10 - Remote Reset and set to 0 - Off. This will disable remote reset and you can then reset faults with the engineer code. You'll still need to replace the...
  16. G

    ADEMCO MICROTECH GALAXY 8 PLUS CP171

    Yes, the Galaxy G2 and Flex series are still available. Honeywell manufacture in China, Poland and Romania. Actually, the quality from China is great. Poland and Romania were a bit rough at the start, but just getting used to bringing up manufacturing. The first generation Flex product had...
  17. G

    ADEMCO MICROTECH GALAXY 8 PLUS CP171

    To answer your question re a replacement panel. A galaxy G2 or Flex panel can be used with your wiring / sensors. As above though, check the fuses.
  18. G

    Galaxy G2 question re Master and Engineer codes

    Glad you're sorted. If you have a recent firmware (1.53 to 1.56) have a look at the SelfMon vmod. It brings the system up to date with Ethernet for remote control and alarm reporting. Disclosure: I run SelfMon. :)
  19. G

    Honeywell Galaxy Flex 1s alarm when installer connexion

    What is OP2 programmed as and do you have a hash in front of the eng code ?
  20. G

    Honeywell Galaxy Flex 1s alarm when installer connexion

    Manager log in and enable eng access in menu 48. Then log in as engineer.