Search results

  1. D

    Vokera Linea 24 issue

    I have, i'm just curious to know that if removing the ignition control module and then putting it back can cause any issues. The boiler is all covered up, i only tested the dp switch, and the fuse in the ignition control unit. Nothing has been 'tampered' with.
  2. D

    Vokera Linea 24 issue

    No, I didn't know that. I've had a heating engineer out to look at it (I was not home at the time and he spoke to my girlfriend.) He advised he reckons it's the PCB that is faulty and said that there is no way of testing the PCB and that you just need to change it and see. He will phone me...
  3. D

    Vokera Linea 24 issue

    Im an electrician and more than capable of replacing pcbs. Im not going near the gas side. The reason the cover was off the boiler is that i was testing the fan proving switch.
  4. D

    Vokera Linea 24 issue

    Video of the fault. I'm thinking ignition board, any thoughts?
  5. D

    Vokera Linea 24 issue

    I have a Vokera Linea 24 combi issue. When the boiler is runnning there is a clicking sound which cuts the pump and boiler out for a split second every 1-2 seconds. This is stopping the water getting up to temperature. Any ideas? Dean.