    16.5kw Electric Cooker, What size Breaker? Pictures added

    Thought I would update one last time, AndyPRK was spot on. We left it on for a few hours and it has been fine since, thanks mate.
  2. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    Thanks Andy I will try that, will be pretty peed off if its gone wrong already, you could buy a small car for what that cost and at 1 day old I was hoping for it to last a bit longer. Although what is strange is how it is doing it. It is a oven/grill and has the option of putting the top...
  3. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    *UPDATE* We have now had the work done, it was done by a different person in the end as the quote for the work to be done by the original electrician was a bit over the top. 4 days to fit a new Consumer unit???? Anyway, really happy with the job he has done and all is well, well that...
  4. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    I will find out why I do need as many as he stated, will have a chat with him about it.
  5. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    Yep I asked him about RCBO and he said nope just RCD, which to be honest for £174 I was a tad disappointed.
  6. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    Thanks for the info, he said it is at cost so will ask him exactly what will be in it and I will do the math, cheers.
  7. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    Just going by what he told me and wrote down Ban all Sheds. He showed me a picture of an empty one, ( he says he buys just the case )he then buys the relevant Rcd's and what not, he said it will cost £174. Again this is just what he told me he wanted to do, I will ask for more and better...
  8. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    Ok John, gotcha He said all circuits will be protected on a RCD, existing and new. As for space it has a big wall to go on but I cannot see where we will use them all, I think he said you have to leave space for upgrades? Thanks again for your help btw
  9. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    Just to clarify, he wants a isolator switch fitted before he will work on it as he said he could not switch off the power safely.
  10. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    Yes he said it would be installed where the current one is. The 21 way is a MK 21 usable way, that's all he told me, though he is coming back to talk about the design of the circuit again.
  11. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    We will be getting a brand new consumer unit john, we would never keep that old thing. Yes the earth is staked outside, but we are running 2 10mm earth cables in for that.
  12. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    Hopefully someone may be able to tell me if I do indeed need an isolation switch fitted or if what is there is in fact ok. Many thanks guys
  13. Untitled

    Untitled

  14. Untitled

    Untitled

  15. Elec

    Elec

  16. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    Spoke with Britannia today and they advised me that the cooker will need: On 6mm t&e a 40amp breaker On 10mm t&e a 45amp breaker They also said it will be fine using the same consumer unit as the rest of the property. I spoke with Npower and another electrician today, Npower will be...
  17. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    Hi, I am not sure what EAL DI training is but I will ask him.
  18. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    Will do, I know you have only posted a few lines but it is people like you that can help jo public save money and time from possible mistakes,..So thank you for that.
  19. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    Thanks again John, It would seem I am going to have to have one of those awkward conservations then. He has good references but is very very cautious it would seem, a few other things he mentioned raised an eyebrow or two. For example: He wants to replace my current 6 way consumer unit...
  20. B

    16.5kw Electric Cooker, What size Breaker? Pictures added

    Thanks John, what do you think about not connecting it up to the new consumer unit? As I say, he wants it on its own consumer unit.