  1. H

    screed vs floating floor

    Hello Peeps I'm not 100% sold on this screed idea ... Nearing the end of my garage conv (hoorah) and for the floor base I've laid sand blinding+dpm+100mm PIR celotex over the existing garage slab, now ready for 75mm sand/cement screed. All as per architect plans. Now that I can see the...
  2. H

    rafter positions

    cheers tony1851, much appreciated for info I went with rafters facing opposite - this passed inspection OK :D yet to nail the end rafters home but plan is to butt these right up to the gable blockwork and single-nail from other side, therefore no need for fiddly cuts of insulation like you...
  3. H

    fitting insulation under rafters

    Hi marlb, I'm due to build my extension roof in the next couple of weeks. drywall screws are what I intend to use. out of interest are your rafters only 4" deep? Mine are 6" which allows for 90mm celotex boards inbetween and 50mm under
  4. H

    rafter positions

    Hi all I'll be framing my new extension roof this weekend. I have a couple of questions regarding the rafter positions, which the plans do confirm but I would appreciate a 2nd opinion as to whether best practice is being used. I have the two gable ends already built and a 9x3 ridge beam...
  5. H

    75mm x 225mm purlins vs steel

    thanks noseall, I'd forgotten my cold-deck insulation will bring the ceiling 4" down the purlins :lol:
  6. H

    75mm x 225mm purlins vs steel

    'lo ... 2nd opinion needed pls? have regs signed off for 1 storey ext. having gable roof of ridge beam + purlins all 75mm x 225mm timbers still considering a vaulted ceiling (as no rafter ties needed anyway) - but obviously purlins will be seen internally and 9" deep. is this acceptable...
  7. H

    DPM position

    mulling this over a bit , there should be very little space for much rainwater to wriggle down onto the dpm if it has a nice thick concrete slab on top and compacted hardcore underneath. so I'll start afresh and lay the hardcore + DPM + concrete now and before the roof is up. this gives me a...
  8. H

    DPM position

    thanks ree. it wasn't the rainwater affecting the concrete I was worried about. if I seal the area with DPM before the roof is up (I am a slow worker) won't the floor area just fill with rainwater that can't drain anywhere? also that I didn't mention, there is a substantial amount of...
  9. H

    DPM position

    quick question ... building a floor sub-base ... can I lay a DPM over the new concrete - rather than between it and the hardcore? would I still need a barrier between the hardcore and concrete (i.e. because of sulphates)? ... reason is, the concrete floor will be built before the...