Search results

  1. G

    Potterton Suprima 40L not attempting to fire up...

    MeldrewsMate thanks for having confidence in me! You are correct that i purchased a recon pcb but with higher grade components...i had to take the first one back that i purchased last thursday as it made the boiler worse...and the second one still wasnt enabling the boiler to ignite. I...
  2. G

    Potterton Suprima 40L not attempting to fire up...

    Gasescape...thanks for contributing...in answer to your question no i didn't do anything like that...i spoke to several people and looked up a lot of info on the subject. there was no need to change to wiring loom as the board was like for like.
  3. G

    Potterton Suprima 40L not attempting to fire up...

    Hi All Thanks for all your comments... Regarding the flow switch, yes it does actually have one fitted (there is a sticker on the front of the boiler stating this too) but i dont seem to be able to upload a photo right now but it's installed on the front flow/return pipe and is an Altecnic...
  4. G

    Potterton Suprima 40L not attempting to fire up...

    Hi All Firstly, a bit of history. 1) Boiler was brand new in a new build in july 2004. 2) PCB had lockout problems in november/december 2009 and i fitted a recon with higher grade components in december 2009 and have had just a handful of lockouts since. 3) On 04/12/14 i purchased...
Back