Search results

  1. 32 Heating

    Biasi 24s boiler howling

    Yea they aren't the best really in my opinion but are easy enough to work on and service.
  2. 32 Heating

    Biasi 24s boiler howling

    I agree with Agile regarding gas pressures. A gas safe engineer will check both working and operating pressures for you. I also advise not altering the gas isolation valve but I'm pretty sure you only did that to test it? Sometimes air restrictions in the combustion chamber can cause howling as...
  3. 32 Heating

    new diaphragm on potterton performa 28

    Ok mate, what is the pressure gauge reading on the bottom right of the boiler?
  4. 32 Heating

    Pressure drop on unvented system

    It sounds to me that your expansion vessel is flat mate. Air should come out the valve. If it's flat the expanding water in your system has nowhere to go so the pressure builds up and the pressure relief valve dumps it. The expansion vessel should be pumped up to around 1bar. The same for the...
  5. 32 Heating

    new diaphragm on potterton performa 28

    Which diaphragm was it mate? Hot water?
  6. 32 Heating

    Boiler Pressure dropping rapidly

    If there are no visible signs of a leak anywhere apart from the filling loop as you turn it (this is common) and the pressure relief valve is discharging you will more than likely find you have a flat or burst expansion vessel in the boiler. This means that as the heating water gets hotter it...
Back
Top