    Heatslave 26/32 Burner/air issue

    I could not locate it on the WB site . I think the part number is 7716190003
  2. J

    Heatslave 26/32 Burner/air issue

    ok so the boiler is running. However there is still a flue issue. I helped install the flue 8 years ago with my uncle. At the bottom of the boiler there is a metal plate in between the start of the flue and the actual boiler. Exhaust fumes go up the middle round pipe and clean air gets drawn...
  3. J

    Heatslave 26/32 Burner/air issue

    it was the original photocell, boiler has not been touched in 8 years. I recon the plumber knacked up on the setting or he tried to up the air settings higher to attempt to compensate for the flue issue. Boiler is running now but probably not at best settings and silver box is off.
  4. J

    Heatslave 26/32 Burner/air issue

    unsure of the part number, however it is the same length as the old one as the old one is still here and the plumber showed me the old one compared to the new one.
  5. J

    Heatslave 26/32 Burner/air issue

    maybe he has set the psi at 110 psi for 28.5kw thus air setting off 15 was too far out? I assume that would make sense in theory lol
  6. J

    Heatslave 26/32 Burner/air issue

    nope but he had a pressure dial thingy on the pump on previous visit. according to the installation manual, if he has tried to set it for 32kw it should be approx. 130 psi and 15 air setting for RS But again I cannot verify that. its a sterling 40 burner
  7. J

    Heatslave 26/32 Burner/air issue

    Well seems to be working for the moment , i will come back with the full story once its fixed properly. Thanks to All for the input. I have stuck with this guy because he done the service and was supposed to do the repair. I have only had one engineer to it. the burner has now been working...
  8. J

    Heatslave 26/32 Burner/air issue

    That makes sense to me. But i don't understand how plumber did not figure it out. lol
  9. J

    Heatslave 26/32 Burner/air issue

    yes he has the kit. he measured pump pressure and used gas analyser last time he was here(when new pump was put on). he never re-tested after he turned the screw down this visit. there is no black smoke and does not stink lol
  10. J

    Heatslave 26/32 Burner/air issue

    he has turned the air screw down. ...fired up straight away. Was at 15 unsure what he turned it down too. There is still an issue, said he would have another look after xmas. Could not put the silver box on as it just choked.
  11. J

    Heatslave 26/32 Burner/air issue

    But surely when plumber adjusts air/combustion he would know this? Are you saying the Air screw needs turned down??? if that's the case i assume the flame is not burning as hot/consistently and the photocell is not sensing the flame?
  12. J

    Heatslave 26/32 Burner/air issue

    That's another half hour running, dropped the boiler thermostat down and it started up as it should when temp dropped. ill let the boiler cool down/turn it off and see what happens.
  13. J

    Heatslave 26/32 Burner/air issue

    I have just turned it off ...been running for over 30 mins rads are hot. now turned it back on after a few mins. Requested heat after a few mins and fired up and running again, ill leave it running for a while again.
  14. J

    Heatslave 26/32 Burner/air issue

    only restricted air for 20 secs or so then took hand off. ...its still running...can hear burner firing on and off as it gets to temp.
  15. J

    Heatslave 26/32 Burner/air issue

    Uncle will not take any money from me. And he is a good distance away. I could have got it serviced free as well but just does not sit rite with me.
  16. J

    Heatslave 26/32 Burner/air issue

    I have just tried ...something... reset boiler 3 times each time its started up/fired and then cut out after 10-15 secs. Then reset and covered air intake at side of burner for 20 secs burner stay on(I assume it will be running rich when I do that). taken hand of still running after 10 mins..ill...
  17. J

    Heatslave 26/32 Burner/air issue

    lol just noticed your location. just drive too Scottish borders and you could fix it lol well he tested it with a torch/room light twice for around 5 mins each time and it seemed to work. as soon as he put it in the photocell hole it cut out. at that point he cleaned the metal thing at the...
  18. J

    Heatslave 26/32 Burner/air issue

    the guy pulled the burner right out away from the chamber. fired it and it lit then tripped. All he did was un-hook the burner from chamber then fire it up/request heat to test then it tripped out. He originally gave it a service and cleaned it all out with hoover said it was not all that dirty...
  19. J

    Heatslave 26/32 Burner/air issue

    ok the boiler was new for 900 pound. the engineer is my uncle(btw he would not take any money for the install). Who trains people to fix/install boilers and is employed by WB. (I do not want to pull in a favour, am not a user). Boiler was not clogged up with soot. The boiler was installed with...
  20. J

    Heatslave 26/32 Burner/air issue

    there is no obstruction from top inspection plate(I had it off to check flue clearance. Blast tube is clear for photocel, you can see the flame if you look through the tube. Baffle above the burner I am unsure, plumber would have to check. The burner cuts off even if removed from boiler and...