  1. C

    Double Glazing

    hi can you be a bit more specific on size of glass
  2. C

    valliant switch 110

    thanks for that gasgeezer.That is the only marking i can find on the entire boiler seems strange does'nt it? cheers chris
  3. C

    valliant switch 110

    hi i have a valliant 110 which wont kick in just saying F 28 on display anybody out there know what fault that is cheers chris
  4. C

    britony combi 80 DHW heats CH ?

    Hi everybody Boiler now working orange wire had broken down tested voltage at board voltage correct checked voltage at 3 way 0.2v replaced wire HOT WATER YIPPEE... or words to that affect A BIG THANK YOU TO EVERYONE who gave me advice. THE OLD 3 WAY STILL DIDNT...
  5. C

    britony combi 80 DHW heats CH ?

    hi everybody im getting 14v on the yellow wire and 0.2v on the orange wire not 24v? does this point to pcb? cheers chris
  6. C

    britony combi 80 DHW heats CH ?

    The diverter presumably "rests" in the CH position. hi tony yes it does i will give it a try tommorow and will post outcome on forum many thanks chris
  7. C

    britony combi 80 DHW heats CH ?

    hi tony Could you explain this in a bit more detail One thing that I would find reasuring is if you can put a diverter valve into the DHW position and fit it to confirm that when the diverter is correctly set for DHW that the boiler will indeed operate on DHW OK. Cheers...
  8. C

    britony combi 80 DHW heats CH ?

    Thanks chris this information is most useful so i can check pcb out and check for voltages stated (i originally come from an electronic background) many thanks chris Will let you know either way cheers
  9. C

    britony combi 80 DHW heats CH ?

    hi everybody yes thats right chris so i could really do with an indepth circuit diagram .The one with the boiler is pretty basic so im going to ring chaff et technical helpline in the morning see if they can give me some output voltages to 3 way.If not suicide is always an...
  10. C

    britony combi 80 DHW heats CH ?

    hi The old 3 way valve does not operate when plugged in loose,looked down the housing with torch to check? cheers chris
  11. C

    britony combi 80 DHW heats CH ?

    cheers meldrew's_mate All connections in right place cant hear motor move but will try old 1 see if i can see it move dont suppose you know the switching voltage from pcb at the moment can only detect 0.4 of a volt going to 3 way. thanks again chris
  12. C

    new door frame too small

    hi If you know the name of the profile (rehau spectus etc) you can buy something called"knock on or add on" that clips in to the profile to add width or height it is mainly for deep plaster lines but would do the job for you and is available in various depths silicone and screw for best...
  13. C

    UPVC Door jammed closed

    Hi roobarbthedog is your door a full panel door or half and half, only if you take the panels out it will allow you a bit of bend in the profile that may allow the rollers to pass the keepers. If not the only other way is to burst the keepers by putting force on the point of roller meets...
  14. C

    britony combi 80 DHW heats CH ?

    hi Im looking for some advice on a britony combi 80. When the hot water tap is turned on the radiators warm up and the hot water system stays cold now according to the fault finding page in the installation manual this fault is down to the 3 way valve? Which has now been changed but fault...