  1. P2AJB

    Central Heating Hot Water Circuit

    Hi We have a Potterton Statesman oil boiler of some age, it works fine and is serviced regularly. Recently the hot water circuit seems to be behaving strangely. The controls on the programmer have both Radiators and hot water on auto and we are in an "on" period. The boiler fires and runs for a...
  2. P2AJB

    Potterton Statesman Utility 130/150

    Hi Guys, thanks for all your advice. I now have a boiler which has ignites correctly everytime............however it is now producing significant amounts of smoke and soot which was the initial problem and where we started in the November service. Just a thought, these problems started when we...
  3. P2AJB

    Potterton Statesman Utility 130/150

    To be discussed when he returns from his 4 week holiday!!!, you were correct back on post 8, wrong nozzle too much air!!!
  4. P2AJB

    Potterton Statesman Utility 130/150

    Bob, Engineer came yesterday, fitted new nozzle as per the Riello manual Danfoss 1.25 60 S, (removing the Delevan 1.25 60 H fitted by the previous bloke) adjusted pump pressure (which was only slightly low) up to 115psi, the recommended (Baxi) CO2 should have been 12% and was running at 7.2...
  5. P2AJB

    Potterton Statesman Utility 130/150

    Thanks Terry will mention it to the man on Tuesday.
  6. P2AJB

    Potterton Statesman Utility 130/150

    So far local man has fitted a new pump, a new coil/solenoid, a new control box, a new photo electric wand, he checked fuel pressure and air mixture and exhaust with an analyser (no print out left) I have changed the capacitor. Different local man coming on Tuesday hopefully with an analyser...
  7. P2AJB

    Potterton Statesman Utility 130/150

    Hi Changed the capacitor, made no difference at all, thanks for the suggestion anyway.
  8. P2AJB

    Potterton Statesman Utility 130/150

    We live in a fairly remote bit of Scotland and he is a man with a sign written van !!! He changed the parts listed above but never mentioned the capacitor once, as none of them fixed the problem and as he is now away for 4 weeks, I thought I would ask on here, some good suggestions but all apart...
  9. P2AJB

    Potterton Statesman Utility 130/150

    Hi Its white plastic with a white cap value 5uf +/- 5%, i'll get it changed. Thanks
  10. P2AJB

    Potterton Statesman Utility 130/150

    Hi Having looked at the parts diagram on Baxi parts list, if it is part number 3008960 Motor Capacitor, no he certainly didn't change it.
  11. P2AJB

    Potterton Statesman Utility 130/150

    Hi No I'm not sure he did. where is it?
  12. P2AJB

    Potterton Statesman Utility 130/150

    Bottom outlet, flow checked and very full and good, filter checked. So over aired. Strangely it fired from cold this morning with no intervention.
  13. P2AJB

    Potterton Statesman Utility 130/150

    At least the local chap set that correctly according to Baxi Technical help line
  14. P2AJB

    Potterton Statesman Utility 130/150

    No local chap just stuck his monitor in the balanced flue and declared it matched the technical advice from Baxi, yes Kero. Any chance the balanced flue is the cause as it was very sooted before the service and I'm not sure he cleaned it?
  15. P2AJB

    Potterton Statesman Utility 130/150

    Hi checked nozzle with Baxi/Potterton, New Danfoss 1.25 60 S fitted, oil pressure set according to technical advice. Emissions checked and match technical helpline advice. I have to admit I don't know about the position of the electrodes, but as it works fine once it has been lit each day is it...
  16. P2AJB

    Potterton Statesman Utility 130/150

    Terrywookfit : Reillo RDB3 burner, new bunded tank fitted 3 years ago floor of tank significantly above burner (15"), boiler has worked perfectly since we bought the house 5 years ago, been serviced annually and has only developed fault since last service. Its the light on the burner which...
  17. P2AJB

    Potterton Statesman Utility 130/150

    Hi We have the above boiler which was made/installed in 2007. Recently it developed a fault after an annual service, at which the boiler was cleaned out removing soot etc, a new nozzle fitted and a new photo electric wand? fitted, the fault causes the burner to fail to start from cold. The...