Search results

  1. P

    What's up with my Boiler (Glowworm Spacesaver 50)

    Thank you for your suggestions K and G. However whatever is making the boiler behave this way has to account for:- 1. the pilot light is stable if the boiler is off (ie the boiler thermostat turned to OFF and electricity switched off.) 2. I get multiple burns of the boiler to bring water tank...
  2. P

    What's up with my Boiler (Glowworm Spacesaver 50)

    I have an ancient boiler, Glowworm Space saver 50, with separate hot water tank. The boiler has been very reliable over the last 40 years, However, lately, I have had to relight the pilot light several times. You are probably thinking that I need a new thermocouple. But if the boiler is not on...
  3. P

    Mira 88 shower (gravity feed) no cold water

    This is the You Tube link referred to above and this is the link for the PDF guide http://resources.kohler.com/plumbing/mira/pdf/p2741-11-mira-88-installation-and-user-guide.pdf see pages 28 to 33
  4. P

    Mira 88 shower (gravity feed) no cold water

    Well, finally the shower is fixed. I've lost count of how many times the mixer unit was removed and re-installed but on at least 4 occasions once reinstalled there was no cold water flow. This happened even when I had a different plumber in to have a go. But this last plumber did finally get it...
  5. P

    Mira 88 shower (gravity feed) no cold water

    OK, so sent email to [email protected]. Will see what they say. If they confirm that problem could have been caused by incorrect reassembly of mixer valve will post further.
  6. P

    Mira 88 shower (gravity feed) no cold water

    Plumber came round to fix leak (not from shower head, but from central spindle) using the Mira 88 service pack (936.12). This fixed the leak, but the shower now behaves in a most curious fashion. With the mixer knob in the COLD position hot water flows but at a low rate. Advancing the knob...
  7. P

    Glow-worm Space Saver 50 - Problem

    Trawling through the forum over the weekend, I found a couple of posts that seem to describe a similar problem with a space saver 50 that I had experienced. In both cases it was suggested that there was a partial blockage of the pilot burner injector. This proved to be the problem in the case...
  8. P

    Glow-worm Space Saver 50 - Problem

    I wonder if anybody has any ideas about the likely cause of a problem that appeared from one day to the next on this boiler. Boiler had been very reliable previously. I have had a gas-safe plumber round to look at it, but after 3 hours he has not come up with a solution. Symptoms are that...
Back