Search results

  1. jcwacky

    Newly Installed Unvented Cylinder - Immersion Heater Not Wired Up?

    The old cylinder didn’t have an immersion heater.
  2. jcwacky

    Newly Installed Unvented Cylinder - Immersion Heater Not Wired Up?

    I recently had a new indirect unvented cylinder installed (to replace my old vented cylinder). I believe the new cylinder includes a backup immersion heater. However, it doesn't look like the installer has wired it up, so I have no way to switch it on. Is it standard (or acceptable) practice...
  3. jcwacky

    Balanced Cold vs T from Outlet

    Does that pic check out ok?
  4. jcwacky

    Balanced Cold vs T from Outlet

    Thanks John. No sign of a NRV. Here's a pic (nothing hidden under lagging):
  5. jcwacky

    Balanced Cold vs T from Outlet

    Anyone able to advise if this is normal practice? Thanks
  6. jcwacky

    Balanced Cold vs T from Outlet

    Just had an invented cylinder installed. It appears that instead of making use of the Balanced Cold on the PRV, my plumber has instead added a T piece to the PRV outlet. So that it directly feeds both the cylinder and all taps & showers etc. So it still seems balanced, but I’m just wondering if...
  7. jcwacky

    Power Shower to Mixer - How to ensure same/better performance?

    You’re probably right, and yeh, thinking about future too when we may add 2nd shower. Upgrading to 22mm could be tricky, so will see how the 15mm pipe copes first. I’m still not clear about the advantages of going for the 3 bar Joules cylinder over the 3.5 bar PremierPlus though.
  8. jcwacky

    Power Shower to Mixer - How to ensure same/better performance?

    Been researching hot water cylinders. Had to discount OSO as their's seem wider than most, and won't fit through my loft hatch. Tempted to go for a Joule, but I don't understand why they operate at only 3 bar, when the PremierPlus is at 3.5 bar? Happy to pay a little more for a little more...
  9. jcwacky

    Power Shower to Mixer - How to ensure same/better performance?

    Thanks Madrab. That's what I'd presumed, and was about to ask. It was actually my installer who initially suggested the Premier Plus, and from looking into it, I liked the fact that it's PRV is set to 3.5 bar, rather than 3 like most others seem to be. But I'm now starting to wonder if it's not...
  10. jcwacky

    Power Shower to Mixer - How to ensure same/better performance?

    Ok, I've managed to take some measurements from the 15mm pipe currently feeding my cold water tank in the loft, that will end up feeding the new unvented cylinder: Static pressure: 3.8 bar Dynamic pressure (with kitchen tap on): 3.5 bar Flow rate: ~27 L/min Flow rate (with kitchen tap on): ~25...
  11. jcwacky

    Power Shower to Mixer - How to ensure same/better performance?

    Thanks. Replacing the 15mm with 22mm would probably require signaficant work in our ensuite and bathroom, so unlikely to do that ATM. Presume putting it up the outside of the house is a silly idea?? :) Is it worth attempting to take some pressure and flow rate measurements from the supply into...
  12. jcwacky

    Power Shower to Mixer - How to ensure same/better performance?

    Thanks. From what I can tell, the pipes that head off to the shower are 28mm, but the mains supply in the house is only 15mm. Is this likely to significantly affect things? Looks like it's about 10 meters of 15mm pipe from the stopcock to cylinder location, with about 6 elbow joints.
  13. jcwacky

    Power Shower to Mixer - How to ensure same/better performance?

    Just took some more measurements: Outside, static: 4.2 bar Outside, dynamic, with cold water tank filling: 4.0 bar Outside, dynamic, with kitchen tap on (~16L/min): 4.0 bar Outside, dynamic, with kitchen tap on and cold water tank filling: 3.6 bar
  14. jcwacky

    Power Shower to Mixer - How to ensure same/better performance?

    Good tips, thanks. My pressure measurement was static.
  15. jcwacky

    Power Shower to Mixer - How to ensure same/better performance?

    Ah ok. Not come across a Joule Cyclone before. Why do you recommend it over the Heatrae Premier? Thanks, that's reassuring. I'm finding some brands of shower are very open about flow rates at different pressures (Bristan), but others not so.
  16. jcwacky

    Power Shower to Mixer - How to ensure same/better performance?

    It's a NewTeam (Showerforce) 201-T and has the pump built in.
  17. jcwacky

    Power Shower to Mixer - How to ensure same/better performance?

    I am considering having my vented hot water cylinder upgraded to an unvented cylinder. Therefore, I will also need to have our power shower replaced with a mixer shower. However, I only wish to do this if the shower performance is going to be the same or better. How do I ensure this will be...
  18. jcwacky

    HW comes on with CH - Wiring?

    Ok, thanks for confirming Jack. The programmer also has a boost button which should still work, so I can just make sure to use that one!
  19. jcwacky

    HW comes on with CH - Wiring?

    Hmm, spoke too soon. Discovered an unintended side effect: If the HW is OFF but the Boost button on the cylinder thermostat is pressed (and the cylinder temp is below set-point), the boiler will fire up and try to heat to cylinder, but it seems that instead of heating the cylinder, it's heating...
Back
Top